The Effects of Instrumental Deadtime on NICER Timing Products

Robbie Webbe,A. J. Young
2024-09-19
Abstract:The X-ray Timing Instrument as part of the Neutron Star Interior Composition Explorer has the potential to examine the time-domain properties of compact objects in regimes not explored by previous timing instruments, due to its combination of high effective area and timing resolution. We consider the effects of instrumental deadtime at a range of effective countrates in a series of observations of the X-ray binary GX 339-4 to determine what effect deadtime has on photometric and Fourier frequency-domain products. We find that there are no significant inconsistencies across the functional detectors in the instrument, and that in the regimes where instrumental deadtime is a limiting factor on observations that previous approaches to dealing with deadtime, as applied to RXTE and other detectors, are still appropriate, and that performing deadtime corrections to lightcurves before creating Fourier products are not necessary at the count rates considered in our analysis.
Instrumentation and Methods for Astrophysics,High Energy Astrophysical Phenomena
What problem does this paper attempt to address?
### What problems does this paper attempt to solve? This paper aims to explore the impact of instrument dead time on the time - domain and frequency - domain products of NICER (Neutron Star Interior Composition Explorer), and to evaluate whether the existing methods for dealing with dead time are applicable to the new - generation timing instruments. Specifically, by analyzing a series of observation data of GX 339 - 4 in the X - ray binary system by NICER, the author studied the impact of dead time on the light curve and Fourier frequency - domain products at different count rates. #### Main research questions include: 1. **The impact of dead time on the light curve**: - Does dead time cause the count rate in the light curve to be suppressed, especially in the case of high count rates? - How to correct the impact of dead time on the light curve to obtain a more accurate "true" count rate? 2. **The impact of dead time on the power spectrum and other frequency - domain products**: - How does dead time affect the power spectrum and other frequency - domain products calculated from the light curve? - Is it necessary to correct the dead time of the light curve before generating Fourier products? 3. **The effectiveness of existing dead - time correction methods**: - Are the dead - time correction methods previously applied to other instruments (such as RXTE) still applicable to NICER? - Are these methods still effective under the high count - rate conditions of NICER? #### Specific research content: - **Data analysis**: The author selected nine observations of GX 339 - 4, covering three different count - rate ranges: low, medium, and high. - **Dead - time measurement**: Calculate the total dead time in each time interval through the dead - time information recorded in the event file, and determine its impact on the observation data. - **Light - curve and power - spectrum generation**: Generate light curves and power spectra using the original data and the data corrected for dead time respectively, and compare the differences between the two. - **Result discussion**: Evaluate the impact of dead time on the observation results, and discuss whether the existing dead - time correction methods are sufficient to cope with the high - resolution characteristics of NICER. #### Conclusion: The author found that within the count - rate range of NICER, the existing dead - time correction methods are still applicable, and at the considered count rates, no additional dead - time correction of the light curve is required before generating Fourier products. This provides an important reference for future research using NICER data. --- I hope this summary can help you understand the main research questions and objectives of the paper. If you have more specific questions or need further explanation, please feel free to let me know!