Spectral interferometric wavefront sensing: a solution for petalometry at Subaru/SCExAO

Vincent Deo,Sebastien Vievard,Manon Lallement,Miles Lucas,Elsa Huby,Kyohoon Ahn,Olivier Guyon,Julien Lozi,Harry-Dean Kenchington-Goldsmith,Sylvestre Lacour,Guillermo Martin,Barnaby Norris,Guy Perrin,Garima Singh,Peter Tuthill
DOI: https://doi.org/10.48550/arXiv.2409.05246
2024-09-09
Abstract:The petaling effect, induced by pupil fragmentation from the telescope spider, drastically affects the performance of high contrast instruments by inducing core splitting on the PSF. Differential piston/tip/tilt aberrations within each optically separated fragment of the pupil are poorly measured by commonly used Adaptive Optics (AO) systems. We here pursue a design of dedicated low-order wavefront sensor -- or petalometers -- to complement the main AO. Interferometric devices sense differential aberrations between fragments with optimal sensitivity; their weakness though is their limitation to wrapped phase measurements. We show that by combining multiple spectral channels, we increase the capture range for petaling aberrations beyond several microns, enough to disambiguate one-wave wrapping errors made by the main AO system. We propose here to implement a petalometer from the multi-wavelength imaging mode of the VAMPIRES visible-light instrument, deployed on SCExAO at the Subaru Telescope. The interferometric measurements obtained in four spectral channels through a 7 hole non-redundant mask allow us to effiiently reconstruct diffierential piston between pupil petals.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
### Problems the paper attempts to solve This paper aims to solve the "petaling effect" caused by the secondary - mirror support structure (spider) of the telescope. This effect seriously affects the performance of high - contrast imaging instruments. Specifically, the petaling effect causes the splitting of the point - spread function (PSF) core, affects the performance of high - efficiency coronagraphs, and makes the speckle structure unstable. **Main problems**: 1. **Influence of the petaling effect**: Due to the pupil fragmentation caused by the secondary - mirror support structure, differential piston/tip/tilt aberrations are generated within each optically separated pupil segment. These aberrations cannot be effectively measured by the commonly used Adaptive Optics (AO) systems. 2. **Limitations of existing AO systems**: Conventional Wavefront Sensors (WFS) perform poorly in dealing with wavefront discontinuities caused by the Low - Wind Effect (LWE) and optically discrete wavefront maps, resulting in pseudo - residual independently evolving piston components in the AO control loop, that is, the petaling effect. 3. **Wavefront splitting problem**: The petaling effect causes the PSF core to split into multiple lobes, which seriously affects high - contrast imaging performance. ### Solutions To solve the above problems, the author proposes a specially designed low - order wavefront sensor - the petalometer - to supplement the main AO system. The specific methods are as follows: 1. **Interferometric techniques**: By using the VAMPIRES visible - light instrument in multi - wavelength imaging mode, deploying a Non - Redundant Mask (NRM) on SCExAO, and using four spectral channels for interferometry, the differential pistons between each petal are effectively reconstructed. 2. **Multi - wavelength interferometry**: Combining multiple spectral channels increases the capture range of petal aberrations to more than a few micrometers, which is sufficient to eliminate the single - wavelength wrapping errors caused by the main AO system. 3. **Experimental verification**: Through laboratory tests and closed - loop experiments, it is proved that this method can significantly reduce the petaling effect and improve high - contrast imaging performance, especially in dealing with wavefront discontinuities caused by LWE. ### Key formulas 1. **Interferometric phase relationship**: \[ C_{ij} \propto \exp(i(\psi_{ij}+\phi_i - \phi_j)) \] where \(C_{ij}\) is the complex amplitude of the interference fringe between the \(i\) - th and \(j\) - th holes, \(\psi_{ij}\) is the bias term, and \(\phi_i\) and \(\phi_j\) are the phases at the two holes respectively. 2. **Differential phase calculation**: \[ \phi_{ij}=\phi_i - \phi_j\ \text{mod}\ 2\pi \] 3. **Pseudo - wavelength calculation**: \[ \Lambda=\frac{\lambda_1\lambda_2}{\lambda_2-\lambda_1} \] where \(\lambda_1\) and \(\lambda_2\) are two different wavelengths. 4. **Unwrapped phase calculation**: \[ \phi(\Lambda)=\phi(\lambda_2)-\phi(\lambda_1)\ \text{mod}\ 2\pi \] 5. **Unambiguous OPD capture range**: \[ \left[-\frac{\Lambda}{2},+\frac{\Lambda}{2}\right] \] Through these techniques and methods, this research has successfully solved the influence of the petaling effect on high - contrast imaging, providing a new solution for future astronomical observations.