Functional kinematic and kinetic requirements of the upper limb during activities of daily living: a recommendation on necessary joint capabilities for prosthetic arms

Christopher Herneth,Amartya Ganguly,Sami Haddadin
2024-08-26
Abstract:Prosthetic limb abandonment remains an unsolved challenge as amputees consistently reject their devices. Current prosthetic designs often fail to balance human-like perfomance with acceptable device weight, highlighting the need for optimised designs tailored to modern tasks. This study aims to provide a comprehensive dataset of joint kinematics and kinetics essential for performing activities of daily living (ADL), thereby informing the design of more functional and user-friendly prosthetic devices. Functionally required Ranges of Motion (ROM), velocities, and torques for the Glenohumeral (rotation), elbow, Radioulnar, and wrist joints were computed using motion capture data from 12 subjects performing 24 ADLs. Our approach included the computation of joint torques for varying mass and inertia properties of the upper limb, while torques induced by the manipulation of experimental objects were considered by their interaction wrench with the subjects hand. Joint torques pertaining to individual ADL scaled linearly with limb and object mass and mass distribution, permitting their generalisation to not explicitly simulated limb and object dynamics with linear regressors (LRM), exhibiting coefficients of determination R = 0.99 pm 0.01. Exemplifying an application of data-driven prosthesis design, we optimise wrist axes orientations for two serial and two differential joint configurations. Optimised axes reduced peak power requirements, between 22 to 38 percent compared to anatomical configurations, by exploiting high torque correlations between Ulnar deviation and wrist flexion/extension joints. This study offers critical insights into the functional requirements of upper limb prostheses, providing a valuable foundation for data-driven prosthetic design that addresses key user concerns and enhances device adoption.
Robotics
What problem does this paper attempt to address?
The paper attempts to address the issue of insufficient functional kinematic and dynamic requirements in upper limb prosthesis design. Specifically: - The paper points out that current prosthesis designs often fail to balance human-like performance with acceptable device weight, leading users to frequently reject these devices. - The research aims to improve prosthetic device design by providing key joint kinematic and dynamic data required for performing Activities of Daily Living (ADL), making them more functional and user-friendly. - By capturing joint motion data from 12 subjects performing 24 types of ADL, the study calculated the functional range of motion (ROM), speed, and torque for the shoulder rotation, elbow joint, radioulnar joint, and wrist joint. - Considering the different mass and inertia properties of the upper limb, as well as the joint torques induced by interaction torques when manipulating experimental objects, the study also used a Linear Regression Model (LRM) to calculate the peak torques required for limbs and objects with different mass and dynamic properties. - Finally, the paper demonstrated the application of a data-driven prosthesis design approach by optimizing the direction of the prosthetic wrist joint axis, which can significantly reduce peak power requirements, thereby improving the efficiency and usability of the prosthesis. Overall, the study aims to provide critical functional requirements data for upper limb prostheses, offering valuable reference data for data-driven prosthesis design to address user concerns and enhance device adoption rates.