2024-08-23
Abstract:Preemptive identification of potential failure under loading of engineering structures is a critical challenge. Our study presents an innovative approach to built-in pre-failure indicators within multiscale structural designs utilizing the design freedom of topology optimization. The indicators are engineered to visibly signal load conditions approaching the global critical buckling load. By showing non-critical local buckling when activated, the indicators provide early warning without compromising the overall structural integrity of the design. This proactive safety feature enhances design reliability. With multiscale analysis, macroscale stresses are related to microscale buckling stability. This relationship is applied through tailored stress constraints to prevent local buckling in general while deliberately triggering it at predefined locations under specific load conditions. Experimental testing of 3D-printed designs confirms a strong correlation with numerical simulations. This not only demonstrates the feasibility of creating structures that can signal the need for load reduction or maintenance but also significantly narrows the gap between theoretical optimization models and their practical application. This research contributes to the design of safer structures by introducing built-in early-warning failure systems.
Computational Engineering, Finance, and Science
What problem does this paper attempt to address?
The key problem that this paper attempts to solve is how to pre - identify potential overload failures in engineering structures, especially providing early warnings when the structure approaches the global critical buckling load. Specifically, the research team proposed an innovative method to embed pre - failure indicators in multi - scale structure design. These indicators can trigger non - critical local buckling under specific load conditions, thus providing early warnings without affecting the overall structural integrity. ### Main Problems and Solutions 1. **Problem Description**: - **Overload Failure**: Catastrophic failure may occur when the load borne by the structure exceeds its ultimate tensile strength (UTS) or causes global buckling. - **Limitations of Existing Monitoring Methods**: Traditional structural health monitoring (SHM) relies on a large number of sensors and frequent inspections, which are not only time - consuming and costly but also can only provide information under specific times and load conditions. 2. **Solutions**: - **Embedded Pre - failure Indicators**: Design the structure through topological optimization so that some areas will have non - critical local buckling when reaching a certain proportion of the critical load, which can be used as an early warning signal for overload. - **Multi - scale Analysis**: Link macro - stress with micro - buckling stability, and use customized stress constraints to prevent local buckling in general cases while intentionally triggering local buckling at specific positions. - **Experimental Verification**: The numerical simulation results were verified through 3D printing and experimental tests, proving the feasibility and effectiveness of this method. ### Research Significance This research provides new ideas for designing safer structures. In particular, by introducing a built - in early warning system, the safety and reliability of structures can be significantly improved. This method not only narrows the gap between theoretical optimization models and practical applications but also provides directions for future research, such as expanding to multiple materials, multiple pre - failure indicators, etc. ### Mathematical Formula Representation In this research, the key formulas involved include: - **Buckling Factor (BF)**: \[ BF=\frac{\text{Critical Buckling Load}}{\text{Applied Load}} \] - **Indicator Buckling Factor**: \[ BF_{\text{indicator}}=\alpha\cdot BF_{\text{critical}} \] where \(\alpha\) is a set safety factor, usually between 0.35 and 0.40. Through these formulas, researchers can accurately control the triggering conditions of pre - failure indicators to ensure timely warnings when the structure approaches the critical state.