Complementary Speckle STED Microscopy

Payvand Arjmand,Samlan Chandran Thodika,Elsa Bivas,Haoyang Li,Martin Oheim,Hiroyuki Yoshida,Etienne Brasselet,Marc Guillon
2024-07-23
Abstract:Stimulated Emission Depletion (STED) microscopy has emerged as a powerful technique providing visualization of biological structures at the molecular level in living samples. In this technique, the diffraction limit is broken by selectively depleting the fluorophore's excited state by stimulated emission, typically using a donut-shaped optical vortex beam. STED microscopy performs unrivalably well in degraded optical conditions such as living tissues. Nevertheless, photo-bleaching and acquisition time are among the main challenges for imaging large volumetric field of views. In this regard, random light beams like speckle patterns have proved to be especially promising for three-dimensional imaging in compressed sensing schemes. Taking advantage of the high spatial density of intrisic optical vortices in speckles -- the most commonly used beam spatial structure used in STED microscopy -- we propose here a novel scheme consisting in performing STED microscopy using speckles. Two speckle patterns are generated at the excitation and the depletion wavelengths, respectively, exhibiting inverted intensity contrasts. We illustrate spatial resolution enhancement using complementary speckles as excitation and depletion beam on both fluorescent beads and biological samples. Our results establish a robust method for super-resolved three-dimensional imaging with promising perspectives in terms of temporal resolution and photobleaching.
Optics
What problem does this paper attempt to address?
The paper aims to address the following issues: 1. **Improving the speed and efficiency of 3D imaging**: Traditional STED microscopy techniques face major challenges such as photobleaching and long imaging times when imaging large-volume samples. This paper proposes a new method using complementary speckle patterns to enhance the speed and efficiency of 3D super-resolution imaging. 2. **Optimizing imaging resolution and phototoxicity**: By using complementary speckle patterns as excitation and depletion beams, this method can reduce unnecessary phototoxicity while maintaining high resolution, thereby improving the imaging quality of biological samples. 3. **Enhancing 3D imaging capabilities**: Utilizing the statistical properties of speckle patterns, 3D imaging can be achieved based on a single 2D scan image. By optimizing the speckle point spread function (PSF), both lateral and axial resolution are further improved. 4. **Achieving real-time adjustment and optimization**: This method can dynamically adjust imaging conditions in real-time operation to minimize photobleaching, processing time, and data volume, thereby achieving efficient and high-quality 3D imaging.