Non-Contact Breath Rate Classification Using SVM Model and mmWave Radar Sensor Data

Mohammad Wassaf Ali,Ayushi Gupta,Mujeev Khan,Mohd Wajid
2024-07-18
Abstract:This work presents the use of frequency modulated continuous wave (FMCW) radar technology combined with a machine learning model to differentiate between normal and abnormal breath rates. The proposed system non-contactly collects data using FMCW radar, which depends on breath rates. Various support vector machine kernels are used to classify the observed data into normal and abnormal states. Prolonged experiments show good accuracy in breath rate classification, confirming the model's efficacy. The best accuracy is 95 percent with the smallest number of support vectors in the case of the quadratic polynomial kernel.
Machine Learning
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to distinguish normal and abnormal breathing rates (BR) by non - contact methods, using frequency - modulated continuous - wave (FMCW) radar technology and machine - learning models, especially support vector machines (SVM). Specifically: 1. **Non - contact data collection**: Traditional breathing rate measurement methods such as manual counting or physical sensors (e.g., chest straps, breathing belts) have contact problems, which may cause patient discomfort or skin irritation and may be impractical during long - term monitoring. Therefore, the research aims to develop a non - contact solution, using FMCW radar sensors to detect small movements related to breathing. 2. **Improving classification accuracy**: By using different SVM kernel functions (linear kernel, radial basis function (RBF) kernel, and quadratic polynomial kernel), the research aims to find the most effective model to accurately distinguish normal and abnormal breathing rates. Experimental results show that the quadratic polynomial kernel uses the fewest number of support vectors while maintaining high accuracy, thereby reducing computational complexity. 3. **Real - time health monitoring applications**: The research also explores how to apply this technology to real - time health monitoring systems to achieve early intervention and timely medical responses, especially in intensive care environments. In summary, the core problem of this paper is to develop a non - contact breathing rate classification system based on FMCW radar and SVM models to improve classification accuracy and patient comfort and provide reliable technical support for real - time health monitoring.