Optimizing the architecture for coherent beat note acquisition in LISA

Philipp Euringer,Gerald Hechenblaikner,Alexander Sell,Francis Soualle,Walter Fichter
2024-06-28
Abstract:The laser interferometer space antenna (LISA) senses gravitational waves by measuring distance fluctuations between three spacecraft (SC). These measurements rely on precise tracking of a beat note phase that is formed on a quadrant-photo-diode (QPD) at each SC by interference of a local laser with a laser sent from a distant SC. The crucial prerequisite of the phase tracking is a successful acquisition of the beat note frequency. This article aims to optimize the carrier-to-noise density ratio (CNR) during this process, and to evaluate the resulting probability of detection (PD). CNR is generally lowest during the beat note acquisition process since pointing accuracy relies on coarse acquisition techniques. Based on analytical models, we examine which combinations of QPD segments for the signal read-out yield the highest CNR, i.e., they are least susceptible to pointing errors. We find from simulations that the highest CNR is ensured by taking the maximum of a combination of two segments in vertical and horizontal direction. For pointing errors (3$\sigma$) of 3.9 $\mu$rad and 4.3 $\mu$rad this yields an improvement of around 3.7 dB and 5.6 dB in CNR, respectively, in comparison to a combination of all four segments. In addition, the PD for various configurations of the baselined Fourier peak detection is analyzed. Here we find that the PD is most sensitive to the CNR compared to the design parameters of the acquisition scheme, in particular the FFT length. Moreover, it is shown that aforementioned improvements in CNR can lead to a significant enhancement of the PD.
Instrumentation and Detectors
What problem does this paper attempt to address?
### Problems Addressed by the Paper The paper primarily focuses on a critical step in gravitational wave detection using the Laser Interferometer Space Antenna (LISA) — the process of acquiring coherent beat note signals. Specifically, the paper aims to optimize the Carrier-to-Noise Ratio (CNR) during the beat note signal acquisition process and evaluate the resulting improvement in Detection Probability (PD). #### Main Objectives: 1. **Improve Carrier-to-Noise Ratio (CNR)**: Optimize the CNR by analyzing different Quadrant Photodiode (QPD) signal reading schemes, especially during the beat note signal acquisition phase when pointing errors are significant. 2. **Enhance Detection Probability (PD)**: Study the detection probability under different configurations and demonstrate how the improvement in CNR significantly enhances the detection probability. #### Key Contributions: - Through simulations, it was found that using only the vertical and horizontal quadrant segments combination can achieve the highest CNR, improving by approximately 3.7 dB and 5.6 dB compared to using all four quadrant segments. - Analyzed the basic scheme based on Fourier peak detection under different configurations and demonstrated that the impact of CNR on detection probability is far greater than other design parameters. - Proposed several optimization schemes to reduce the impact of pointing errors on CNR, thereby improving the beat note signal detection performance. Through these analyses, the paper aims to provide a more robust method for beat note signal acquisition in the LISA system for gravitational wave detection.