Photoacoustic methane detection assisted by a gas-filled anti-resonant hollow-core fiber laser

Cuiling Zhang,Jose Enrique Antonio-Lopez,Rodrigo Amezcua-Correa,Yazhou Wang,Christos Markos
2024-06-21
Abstract:Photoacoustic spectroscopys (PAS)-based methane (CH4) detectors have garnered significant attention with various developed systems using near-infrared (NIR) laser sources, which requires high-energy and narrow-linewidth laser sources to achieve high-sensitivity and low-concentration gas detection. The anti-resonant hollow-core fiber (ARHCF) lasers in the NIR and mid-infrared (MIR) spectral domain show a great potential for spectroscopy and high-resolution gas detection. In this work, we demonstrate the generation of a frequency-comb-like Raman laser with high pulse energy spanning from ultraviolet (UV) (328 nm) to NIR (2065 nm wavelength) based on a hydrogen (H2)-filled 7-ring ARHCF. The gas-filled ARHCF fiber is pumped with a custom-laser at 1044 nm with ~100 {\mu}J pulse energy and a few nanoseconds duration. Through stimulated Raman scattering process, we employ the sixth-order Stokes as case example located at ~1650 nm to demonstrate how the developed high-energy and narrow-linewidth laser source can effectively be used to detect CH4 in the NIR-II region using the photoacoustic modality. We report the efficient detection of CH4 with sensitivity as low as ~550 ppb with an integration time of ~40 s. In conclusion, the main goal of this work is to demonstrate and emphasize the potential of the gas-filled ARHCF laser technology for compact next-generation spectroscopy across different spectral regions.
Optics
What problem does this paper attempt to address?
The main objective of this paper is to demonstrate and emphasize the potential applications of gas-filled anti-resonant hollow-core fiber (ARHCF) laser technology in different spectral regions. Specifically, the study generates a frequency comb-like Raman laser source using a hydrogen-filled ARHCF laser and demonstrates how this high-energy, narrow-linewidth laser source can be used to detect methane (CH₄) in the near-infrared (NIR) region. The study achieved effective methane detection with a sensitivity as low as approximately 550 ppb and an integration time of 40 seconds. Additionally, the research explores the possibility of using the same laser source for dual gas detection (methane and carbon dioxide). Overall, the paper aims to showcase the application potential and superior performance of this novel laser technology in the field of gas spectroscopy.