Accurate estimate of the ESPRESSO fiber-injection losses inferred from integrated field-stabilization images

Tobias M. Schmidt
2024-06-11
Abstract:Ground-based astronomy is unavoidably subject to the adverse effect of atmospheric turbulence, a.k.a. the seeing, which blurs the images and limits the achievable spatial resolution. For spectroscopic observations, it leads to slit or fiber-injection losses, since not all photons distributed over the extended seeing disk can be captured. These losses might have a very substantial impact on the overall efficiency of a spectrograph and are naturally highly variable. Assessing the fiber-injection losses requires accurate information about the image quality (IQ) delivered by the telescope to the instrument over the course of the observations, which, however, is often not directly available. ESPRESSO provides acquisition and field-stabilization images attached to the science data and thus offers the opportunity for a post-processing analysis. Here, we present a novel method to infer the IQ profile and fiber-injection losses from the integrated field-stabilization images, utilizing the spill-over light that does not get injected into the fiber. We validate these measurements against the IQ observed in the acquisition images and determine that our method delivers unbiased estimates with a scatter of 0.11" for the FWHM of the profile and 15% in terms of fiber-injection losses. This compares favorably to the estimates derived from either the differential image motion monitor (DIMM) or the telescope guide probe sensors and therefore represents a valuable tool to characterize the instrument efficiency and to correct raw spectra for fiber-injection losses.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
### What problem does this paper attempt to solve? This paper aims to solve the problem of fiber - injection losses in ground - based astronomical observations due to atmospheric turbulence (i.e., "seeing"). Specifically, the author proposes a new method to estimate the image quality (IQ) and fiber - injection losses by analyzing the field - stabilization images of the ESPRESSO spectrometer. #### Background and Problem Description 1. **The Influence of Seeing** - Ground - based astronomical observations are inevitably affected by atmospheric turbulence, which causes image blurring and limits the achievable spatial resolution. - For spectral observations, seeing can cause slit or fiber - injection losses because not all photons distributed on the extended seeing disk can be captured. These losses can have a significant impact on the overall efficiency of the spectrometer and are highly variable. 2. **Limitations of Existing Measurement Methods** - Assessing fiber - injection losses requires an accurate understanding of the image quality (IQ) transmitted by the telescope to the instrument throughout the observation process, but this information is usually not directly available. - Existing IQ monitoring devices such as the Differential Image Motion Monitor (DIMM) or the telescope guide probe sensors, although providing some information, their measurement results do not always accurately reflect the IQ under actual observation conditions. 3. **Research Objectives** - Propose a new method to infer IQ and fiber - injection losses using the spill - over light in the field - stabilization images of the ESPRESSO spectrometer. - Verify the accuracy of this method and compare it with the measurement results of existing DIMM and guide probe sensors to evaluate its value in characterizing instrument efficiency and correcting raw spectral data. #### Method Overview The author achieved this goal through the following steps: 1. **Data Sources** - Use the acquisition images and field - stabilization images provided by the ESPRESSO spectrometer as the research objects. 2. **New Method Development** - Propose a new method based on the spill - over light in the field - stabilization images to infer IQ and fiber - injection losses. 3. **Verification and Comparison** - Compare and verify the IQ and fiber - injection loss estimates obtained by the new method with the IQ in the acquisition images and the measurement results of DIMM and guide probe sensors. 4. **Results and Conclusions** - The new method can provide an unbiased estimate, with an FWHM scatter of 0.11 arcseconds and a fiber - injection loss error of 15%. This is more accurate than the estimates of DIMM or guide probe sensors, so it can be used as an effective tool for characterizing instrument efficiency and correcting spectral data. Through this method, researchers hope to estimate fiber - injection losses more accurately, thereby improving the efficiency and signal - to - noise ratio (S/N) of spectral observations.