ICU-Sepsis: A Benchmark MDP Built from Real Medical Data

Kartik Choudhary,Dhawal Gupta,Philip S. Thomas
2024-10-14
Abstract:We present ICU-Sepsis, an environment that can be used in benchmarks for evaluating reinforcement learning (RL) algorithms. Sepsis management is a complex task that has been an important topic in applied RL research in recent years. Therefore, MDPs that model sepsis management can serve as part of a benchmark to evaluate RL algorithms on a challenging real-world problem. However, creating usable MDPs that simulate sepsis care in the ICU remains a challenge due to the complexities involved in acquiring and processing patient data. ICU-Sepsis is a lightweight environment that models personalized care of sepsis patients in the ICU. The environment is a tabular MDP that is widely compatible and is challenging even for state-of-the-art RL algorithms, making it a valuable tool for benchmarking their performance. However, we emphasize that while ICU-Sepsis provides a standardized environment for evaluating RL algorithms, it should not be used to draw conclusions that guide medical practice.
Machine Learning
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to construct a benchmark environment that can be used to evaluate the performance of reinforcement learning (RL) algorithms, especially for the complex and challenging sepsis management task. Specifically, the paper introduces ICU - Sepsis, which is a Markov decision process (MDP) environment constructed based on real - world medical data. This environment aims to simulate the personalized treatment of sepsis patients in the intensive care unit (ICU) and provides a standardized test platform so that researchers can evaluate the performance of different RL algorithms in dealing with this real - world problem. ### Main Objectives 1. **Construct a Standard MDP Environment**: Use real - world medical data to construct an MDP environment that can simulate the treatment process of sepsis patients in the ICU. 2. **Evaluate the Performance of RL Algorithms**: Provide a standardized environment so that researchers can evaluate the performance of different RL algorithms in dealing with complex medical problems. 3. **Promote the Application of RL in the Medical Field**: By providing an easy - to - use environment, promote further research and application of RL technology in the medical field. ### Key Contributions - **Light - weight and Highly Compatible**: ICU - Sepsis is a tabular MDP, which is small in size and compatible with multiple RL algorithms, and is easy to be quickly integrated into different benchmark suites. - **Highly Challenging**: Even the most advanced RL algorithms face challenges in this environment, which makes it a valuable tool for evaluating algorithm performance. - **Protect Patient Privacy**: The environmental parameters only provide the overall statistical summary of patient data, ensuring the security of patient privacy. ### Methods - **Data Sources**: Use the real - patient data in the MIMIC - III database, which contains data of more than 40,000 ICU patients. - **Discretization of States and Actions**: Discretize the patient's state into 716 states and the possible medical interventions into 25 actions. - **Reward Mechanism**: A + 1 reward is given for patient survival, no reward for death, and a 0 reward for intermediate steps. - **Environment Construction**: Cluster the states by the K - means clustering algorithm and set reasonable transition thresholds to ensure the accuracy of the transition probabilities. ### Experimental Results - **Baseline Performance**: The average returns of the random policy, expert policy, and optimal policy are 0.78, 0.78, and 0.88 respectively, indicating that even randomly selecting actions can achieve performance close to the expert level. - **Algorithm Evaluation**: The experiment evaluated five common RL algorithms (Sarsa, Q - Learning, Deep Q - Network, Soft Actor - Critic, Proximal Policy Optimization). The results show that these algorithms require a large amount of training to converge, and not all algorithms can achieve performance close to the optimal. ### Limitations - **Non - comprehensive Medical Simulation**: Although ICU - Sepsis simulates some aspects of sepsis treatment, it does not cover all clinical factors and should not be used for actual medical decision - making. - **Generalization Ability of Policies**: The generalization ability of the learned policies in different scenarios has not been tested, and these policies may perform poorly when the treatment standards change. ### Future Work - **Expand Functions**: Further improve ICU - Sepsis, add more medical scenario simulations, and improve its applicability to different medical problems. - **Multi - modal Data Fusion**: Combine more types of medical data, such as imaging data, to enhance the complexity and authenticity of the environment. - **Inter - disciplinary Cooperation**: Cooperate with medical experts to further verify and improve the model to make it closer to the actual medical needs. In conclusion, this paper provides a standardized platform for evaluating the performance of RL algorithms in complex medical problems by constructing the ICU - Sepsis environment, which promotes the application and development of RL technology in the medical field.