Extraction of Weak Surface Diaphragmatic Electromyogram Using Modified Progressive FastICA Peel-Off

Yao Li,Dongsheng Zhao,Haowen Zhao,Xu Zhang,Min Shao
2024-06-28
Abstract:Diaphragmatic electromyogram (EMGdi) contains crucial information about human respiration therefore can be used to monitor respiratory condition. Although it is practical to record EMGdi noninvasively and conveniently by placing surface electrodes over chest skin, extraction of such weak surface EMGdi (sEMGdi) from great noisy environment is a challenging task, limiting its clinical use compared with esophageal EMGdi. In this paper, a novel method is presented for extracting weak sEMGdi signal from high-noise environment based on fast independent component analysis (FastICA), constrained FastICA and a peel-off strategy. It is truly a modified version of of progressive FastICA peel-off (PFP) framework, where the constrained FastICA helps to extract and refine respiration-related sEMGdi signals, while the peel-off strategy ensures the complete extraction of weaker sEMGdi components. The method was validated using both synthetic and clinical signals. It was demonstrated that our method was able to extract clean sEMGdi signals efficiently with little distortion. It outperformed state-of-the-art comparison methods in terms of sufficiently high SIR and CORR at all noise levels when tested on synthetic data, while also achieved an accuracy of 95.06% and a F2-score of 96.73% for breath identification on clinical data. The study presents a valuable solution for noninvasive extraction of sEMGdi signals, providing a convenient and valuable way of ventilator synchrony with a significant potential in aiding respiratory rehabilitation and health.
Medical Physics,Human-Computer Interaction
What problem does this paper attempt to address?
The problem this paper attempts to address is the extraction of weak surface diaphragm electromyography (sEMGdi) signals from highly noisy environments. Specifically, sEMGdi signals in clinical applications are affected by various interferences and noises, such as electrocardiogram (ECG) interference, electrode motion artifacts, and environmental noise. This results in low-quality sEMGdi signals recorded from surface electrodes, making them difficult to use for applications such as respiratory monitoring and assisted ventilation. Therefore, the paper proposes a new method based on Fast Independent Component Analysis (FastICA), constrained FastICA, and a peeling strategy to effectively extract clean sEMGdi signals and enhance their clinical application value. The main contributions of the paper include: 1. **Method Innovation**: An improved Progressive FastICA Peeling framework (PFP) is proposed, which combines constrained FastICA and a peeling strategy to more accurately extract and refine respiration-related sEMGdi signals. 2. **Performance Validation**: The effectiveness of the method is validated through synthetic data and clinical data. The results show that the method can efficiently extract clean sEMGdi signals under different noise levels and demonstrates high accuracy and F2 scores in respiratory detection tasks. 3. **Clinical Application Potential**: The method provides a convenient and valuable means for non-invasive measurement of sEMGdi signals, contributing to respiratory rehabilitation and health monitoring, with significant potential in assisted ventilation synchronization. In summary, this paper aims to address the noise interference problem in current sEMGdi signal extraction, proposing a new signal processing method that provides strong support for clinical applications.