Computational analysis of a contraction rheometer for the grade-two fluid model

Sara Pollock,L. Ridgway Scott
2024-04-04
Abstract:We explore the possibility of simulating the grade-two fluid model in a geometry related to a contraction rheometer, and we provide details on several key aspects of the computation. We show how the results can be used to determine the viscosity $\nu$ from experimental data. We also explore the identifiability of the grade-two parameters $\alpha_1$ and $\alpha_2$ from experimental data. In particular, as the flow rate varies, force data appears to be nearly the same for certain distinct pairs of values $\alpha_1$ and $\alpha_2$; however we determine a regime for $\alpha_1$ and $\alpha_2$ for which the parameters may be identifiable with a contraction rheometer.
Numerical Analysis
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: **How to simulate and identify the parameters of the grade - two fluid model through the contraction rheometer?** Specifically, the authors explored the possibility of simulating the grade - two fluid model in the geometry related to the contraction rheometer and introduced several key aspects in the calculation in detail. They showed how to determine the viscosity \( \nu \) from the experimental data and studied the possibility of identifying the grade - two fluid model parameters \( \alpha_1 \) and \( \alpha_2 \) from the experimental data. In particular, when the flow rate changes, the force data for some different pairs of \( \alpha_1 \) and \( \alpha_2 \) are almost the same; however, they determined a parameter range within which the contraction rheometer can be used to identify these parameters. ### Main problem decomposition: 1. **Simulating the grade - two fluid model**: - The researchers explored the methods of simulating the grade - two fluid model in the geometry of the contraction rheometer. - Specific methods for numerically solving the model equations were provided, including new algorithms and implementations that support general parameters and inflow boundary conditions. 2. **Parameter identification**: - By analyzing the force integral data under different parameter combinations, the researchers attempted to find a parameter range so that \( \alpha_1 \) and \( \alpha_2 \) can be uniquely determined from the experimental data. - Special attention was paid to the phenomenon that the force data of some parameter pairs are almost the same when the flow rate changes, and attempts were made to find the conditions that can distinguish these parameters. 3. **Viscosity determination**: - It was shown how to determine the viscosity \( \nu \) from the experimental data, which is an important step in the rheometer's measurement of fluid properties. ### Mathematical model: The basic equations of the grade - two fluid model are: \[ -\nu \Delta u + u \cdot \nabla u + \nabla p = \nabla \cdot \mathbf{\tau}, \quad \nabla \cdot u = 0 \text{ in } \Omega, \quad u = g \text{ on } \partial \Omega \] where, \[ \mathbf{\tau} = \alpha_1 \left( u \cdot \nabla A - A \circ (\nabla u)^T - (\nabla u) \circ A \right)+(2\alpha_1 + \alpha_2) A \circ A \] and \( A=\nabla u + (\nabla u)^T \). ### Experimental design: - Experiments were carried out using the contraction rheometer by changing the flow rate and measuring the corresponding force data. - Force integrals were calculated through numerical simulation to analyze the results under different parameter combinations. ### Conclusion: The main conclusion of the research is that although the force data are difficult to distinguish under certain parameter combinations, within a specific parameter range, the contraction rheometer can be used to identify the parameters \( \alpha_1 \) and \( \alpha_2 \) of the grade - two fluid model. This provides theoretical basis and technical support for future research.