Investigation of nanophotonic lithium niobate waveguides for on-chip evanescent wave sensing

Nathan A. Harper,Emily Y. Hwang,Philip A. Kocheril,Tze King Lam,Scott K. Cushing
2024-05-16
Abstract:Thin-film lithium niobate is a promising photonic platform for on-chip optical sensing because both nonlinear and linear components can be fabricated within one integrated device. To date, waveguided sample interactions for thin-film lithium niobate are not well explored. Compared to other integrated platforms, lithium niobate's high refractive index, birefringence, and angled sidewalls present unique design challenges for evanescent wave sensing. Here, we compare the performance of the quasi-transverse-electric (TE) and the quasi-transverse-magnetic (TM) mode for sensing on a thin-film lithium niobate rib waveguide with a 5 mM dye-doped polymer cladding pumped at 406 nm. We determine that both modes have propagation losses dominated by scatter, and that the absorption due to the sample only accounts for 3% of the measured losses for both modes. The TM mode has better overlap with the sample than the TE mode, but the TM mode also has a stronger propagation loss due to sidewall and sample induced scattering (32.5 $\pm$ 0.3 dB/cm) compared to the TE mode (23.0 $\pm$ 0.2 dB/cm). The TE mode is, therefore, more appropriate for sensing. Our findings have important implications for on-chip lithium niobate-based sensor designs.
Optics,Applied Physics
What problem does this paper attempt to address?
This paper mainly discusses the problem of evaporative wave sensing using lithium niobate waveguides in nanophotonic chips. In the study, the authors used model thin-film lithium niobate ridge waveguides and 406-nanometer laser diodes to analyze the scattering and fluorescence distributions of dye-doped polymer films. They found that although the quasi-transverse magnetic (TM) mode had stronger interaction with the sample, the scattering loss (32.5 ± 0.3 dB/cm) in the TM mode was much higher than that in the quasi-transverse electric (TE) mode (23.0 ± 0.2 dB/cm), which actually reduced the molecular excitation for a given input power. Therefore, the TE mode may be more suitable for sensing applications. The paper also pointed out that although the TM mode theoretically has a higher absorption cross-section, scattering loss is a major issue in practical devices, and the sample absorption only accounts for about 3% of the experiment. In addition, the study emphasized the importance of considering factors such as subwavelength defects on waveguide surfaces, sample scattering, and material interface refractive index contrast, which can affect the efficiency of practical devices. Through experimental measurements and model comparisons, the paper provides guidance for future fully integrated sensors on the lithium niobate platform, especially considering the TE mode's access to the strongest optical and electro-optical nonlinearity in X-cut thin-film lithium niobate. Future research can focus on reducing waveguide scattering loss and introducing microfluidic systems for analyzing liquid samples to improve sensor performance.