Statistical modelling and Bayesian inversion for a Compton imaging system: application to radioactive source localisation

Cecilia Tarpau,Ming Fang,Konstantinos C. Zygalakis,Marcelo Pereyra,Angela Di Fulvio,Yoann Altmann
2024-02-16
Abstract:This paper presents a statistical forward model for a Compton imaging system, called Compton imager. This system, under development at the University of Illinois Urbana Champaign, is a variant of Compton cameras with a single type of sensors which can simultaneously act as scatterers and absorbers. This imager is convenient for imaging situations requiring a wide field of view. The proposed statistical forward model is then used to solve the inverse problem of estimating the location and energy of point-like sources from observed data. This inverse problem is formulated and solved in a Bayesian framework by using a Metropolis within Gibbs algorithm for the estimation of the location, and an expectation-maximization algorithm for the estimation of the energy. This approach leads to more accurate estimation when compared with the deterministic standard back-projection approach, with the additional benefit of uncertainty quantification in the low photon imaging setting.
Applications,Image and Video Processing,Mathematical Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: **How to estimate the position and energy of point sources from the data recorded by the Compton imager**. Specifically, the researchers developed a new statistical forward model for processing the data in this new - type Compton imaging system and solved the inverse problem through the Bayesian framework, thereby estimating the position and energy of the radiation source more accurately. ### Detailed Interpretation #### 1. Research Background The traditional Compton camera consists of two - layer sensors. The first - layer sensor interacts with incident photons through Compton scattering, and the second - layer sensor absorbs the scattered photons. However, this traditional design has limitations in certain application scenarios, especially when a wide field of view is required. For this reason, the researchers developed a new - type Compton imaging system (CI). Its sensors can be used as scatterers or absorbers and are suitable for high - energy - source imaging and application scenarios requiring a full field of view. #### 2. Problems Solved This paper aims to solve the following two main problems: - **Estimating the position and energy of point sources**: Estimating the position and energy of point sources from the data recorded by the Compton imaging system. - **Handling measurement noise and background noise**: Considering the influence of measurement noise from different sources and background noise to improve the accuracy of estimation. #### 3. Method Overview To achieve the above goals, the author proposes the following methods: - **Statistical forward model**: A new statistical forward model was constructed, which can handle the characteristics of the new - type Compton imaging system. - **Bayesian inverse problem solving**: The inverse problem was formulated and solved in the Bayesian framework. The Metropolis - within - Gibbs algorithm was used to estimate the position, and the Expectation - Maximization (EM) algorithm was used to estimate the energy. - **Uncertainty quantification**: Compared with the traditional deterministic back - projection method, this method provides more accurate estimates and can perform uncertainty quantification in low - photon imaging settings. #### 4. Formula Summary The key formulas involved in the paper include: - Compton scattering angle formula: \[ \omega(E_0, E_1)=\arccos\left(1 - \frac{m c^2}{E_0}\left(\frac{1}{E_0 - E_1}-\frac{1}{E_0}\right)\right) \] - Klein - Nishina formula: \[ f(E_1|E_0, CS_1)=\frac{\phi_{E_0}(E_1)}{\int_{E_{1,\text{min},cs}}^{E_{1,\text{max},cs}}\phi_{E_0}(x)\,dx} \] where \[ \phi_{E_0}(x)=\left(\frac{E_0 - x}{E_0}\right)^2\left(\frac{E_0 - x}{E_0 + x}\right)\left(\frac{E_0 - x}{E_0 - x}+\left(1 - \frac{m c^2}{E_0}\left(\frac{x}{E_0 - x}\right)\right)^2\right)\sqrt{1-\left(1 - \frac{m c^2}{E_0}\left(\frac{x}{E_0 - x}\right)\right)} \] #### 5. Conclusion Through the above methods, the researchers can estimate the position and energy of the radiation source more accurately in low - photon imaging settings and provide the ability of uncertainty quantification. This provides strong support for applications in fields such as nuclear safety and environmental radiation monitoring. If you have more specific questions or need further explanation, please feel free to let us know!