Quasi-real-time dual-comb spectroscopy with 750-MHz Yb:fiber combs

Haochen Tian,Runmin Li,Lukasz A. Sterczewski,Takashi Kato,Akifumi Asahara,Kaoru Minoshima
DOI: https://doi.org/10.1364/OE.460720
2024-01-30
Abstract:We present quasi-real-time dual-comb spectroscopy (DCS) using two Yb:fiber combs with ~750 MHz repetition rates. A computational coherent averaging technique is employed to correct timing and phase fluctuations of the measured dual-comb interferogram (IGM). Quasi-real-time phase correction of 1-ms long acquisitions occurs every 1.5 seconds and is assisted by coarse radio frequency (RF) phase-locking of an isolated RF comb mode. After resampling and global offset phase correction, the RF comb linewidth is reduced from 200 kHz to ~1 kHz, while the line-to-floor ratio increases 13 dB in power in 1 ms. Using simultaneous offset frequency correction in opposite phases, we correct the aliased RF spectrum spanning three Nyquist zones, which yields an optical coverage of ~180 GHz around 1.035 $\mu$m probed on a sub-microsecond timescale. The absorption profile of gaseous acetylene is observed to validate the presented technique.
Optics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to implement quasi - real - time dual - comb spectroscopy (DCS) in a free - running ytterbium - doped fiber frequency comb (Yb:fiber combs) with a high repetition rate (about 750 MHz). Specifically, the paper focuses on the following points: 1. **Phase Noise Correction**: The paper proposes a computational coherent averaging (CoCoA) algorithm to correct the relative phase noise in the interferogram (IGM) signals generated by two free - running frequency combs. This noise can seriously affect the quality of spectral measurements. 2. **Handling of Multiple Nyquist Zones**: Due to the use of high - repetition - rate frequency combs, aliasing problems in multiple Nyquist zones are caused. The paper solves this problem by simultaneously performing in - phase and anti - phase offset frequency corrections, enabling the recovery of spectra spanning three Nyquist zones. 3. **Quasi - Real - Time Processing**: To achieve quasi - real - time processing, the paper introduces a simple phase - locking scheme. By using feedback control of the pump power to stabilize a specific radio - frequency comb line (70 MHz), it ensures that the comb line does not drift out of the filter bandwidth over a long period. 4. **Application Verification**: The paper verifies the effectiveness of the proposed quasi - real - time dual - comb spectroscopy technique by observing the absorption characteristics of acetylene gas. Experimental results show that after phase correction, the line width of the radio - frequency comb line is reduced from 200 kHz to about 1 kHz, and the signal - to - noise ratio is improved by 13 dB. In summary, the main objective of this paper is to develop a technique that can implement quasi - real - time dual - comb spectroscopy in a high - repetition - rate free - running frequency comb system, and solve the resulting phase - noise and multi - Nyquist - zone aliasing problems, thereby improving the accuracy and reliability of spectral measurements.