High-sensitivity dual-comb and cross-comb spectroscopy across the infrared using a widely-tunable and free-running optical parametric oscillator

Carolin P. Bauer,Zofia A. Bejm,Michelle K. Bollier,Justinas Pupeikis,Benjamin Willenberg,Ursula Keller,Christopher R. Phillips
2024-03-13
Abstract:Coherent dual-comb spectroscopy (DCS) enables high-resolution measurements at high speeds without the trade-off between resolution and update rate inherent to mechanical delay scanning approaches. However, high system complexity and limited measurement sensitivity remain major challenges for DCS. Here, we address these challenges via a wavelength-tunable dual-comb optical parametric oscillator (OPO) combined with an up-conversion detection method. The OPO is tunable in the short-wave infrared (1300-1670 nm range) and mid-infrared (2700- 5000 nm range) where many molecules have strong absorption bands. Both OPO pump beams are generated in a single spatially-multiplexed laser cavity, while both signal and idler beams are generated in a single spatially-multiplexed OPO cavity. The near-common path of the combs in this new configuration enables comb-line-resolved and aliasing-free measurements in free-running operation. By limiting the instantaneous idler bandwidth to below 1 THz, we obtain a high power per comb line in the mid-infrared of up to 160 $\mu$W. With a novel intra-cavity nonlinear up-conversion scheme based on cross-comb spectroscopy, we leverage these power levels while overcoming the sensitivity limitations of direct mid-infrared detection, leading to a high signal-to-noise ratio (50.2 dB Hz$^{1/2}$) and record-level dual-comb figure of merit (3.5\times 10^8 Hz$^{1/2}$). As a proof of concept, we demonstrate the detection of methane with 2-ppm concentration over 3-m path length. Our results demonstrate a new paradigm for DCS compatible with high-sensitivity and high-resolution measurements over a wide spectral range.
Optics
What problem does this paper attempt to address?
The paper aims to address two major challenges in dual-comb spectroscopy (DCS) technology: limited signal-to-noise ratio (SNR) and high system complexity. To tackle these challenges, researchers developed a new light source based on a tunable optical parametric oscillator (OPO) and combined it with a novel upconversion detection method. Specifically: 1. **Improving Measurement Sensitivity**: By limiting the instantaneous idler bandwidth to below 1 THz, the researchers achieved up to 160 microwatts of power per comb line in the mid-infrared region. Utilizing cross-comb spectroscopy, they overcame the sensitivity limitations of direct mid-infrared detection, achieving a high SNR (50.2 dB Hz^(-1/2)) and record dual-comb performance metrics (3.5×10^8 Hz^(-1/2)). 2. **Simplifying System Complexity**: Traditional DCS systems typically require multiple cavities and corresponding feedback loops to maintain stability. The method proposed in this paper employs a single-cavity dual-comb concept, realizing a dual-comb light source within one laser cavity and one OPO cavity through spatial multiplexing technology, significantly reducing system complexity. Through these innovations, the study demonstrates a new paradigm for high-sensitivity and high-resolution measurements across a wide spectral range, particularly in the short-wave infrared (1300-1670 nm) and mid-infrared (2700-5000 nm) regions. As a proof of concept, the researchers successfully detected methane at a concentration of 2 ppm over a 3-meter path length. Additionally, further cross-comb spectroscopy measurements were conducted on a low-pressure acetylene sample cell, showcasing the system's wide spectral coverage and high-resolution capabilities.