The TES-based Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU: a large area silicon microcalorimeter for background particles detection

M. D'Andrea,C. Macculi,S. Lotti,L. Piro,A. Argan,G. Minervini,G. Torrioli,F. Chiarello,L. Ferrari Barusso,E. Celasco,G. Gallucci,F. Gatti,D. Grosso,M. Rigano,D. Brienza,E. Cavazzuti,A. Volpe
DOI: https://doi.org/10.1007/s10909-023-03034-5
2024-01-20
Abstract:We are developing the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last CryoAC single-pixel prototype. It is based on a 1 cm2 silicon absorber sensed by a single 2mm x 1mm Ir/Au TES, featuring an on-chip heater for calibration and diagnostic purposes. We have illuminated the sample with 55Fe (6 keV line) and 241Am (60 keV line) radioactive sources, thus studying the detector response and the heater calibration accuracy at low energy. Furthermore, we have operated the sample in combination with a past-generation CryoAC prototype. Here, by analyzing the coincident detections between the two detectors, we have been able to characterize the background spectrum of the laboratory environment and disentangle the primary (i.e. cosmic muons) and secondaries (mostly secondary photons and electrons) signatures in the spectral shape.
Instrumentation and Methods for Astrophysics,Instrumentation and Detectors
What problem does this paper attempt to address?
The problem this paper attempts to address is: The ATHENA X-IFU (X-ray Integral Field Unit) instrument's sensitivity is limited by the impact of background particles when detecting high-energy phenomena in the universe. To reduce the interference from these background particles, the research team developed a Cryogenic Anti-Coincidence detector (CryoAC). This detector is based on Transition Edge Sensors (TES) and can identify and exclude signals generated by background particles, thereby improving the overall performance of the X-IFU. Specifically, the paper presents the test results of the latest single-pixel prototype (DM127) of the CryoAC. By using radioactive sources (such as 55Fe and 241Am) for irradiation experiments, the research team evaluated the detector's response characteristics, energy resolution, and low-energy threshold. Additionally, they analyzed the background spectrum in the laboratory environment by operating it in conjunction with an earlier CryoAC prototype (AC-S9), distinguishing signals from cosmic muons and other secondary particles. These test results not only validate the design and performance of the CryoAC but also provide important insights for further optimization of the detector's design.