Exploring Advanced Detector Technologies for Muon Radiography Applications

Amrutha Samalan,Yassar Assran,Carlos Andres Diaz Escorcia,Basma EIMahdy,Yanwen Hong,Prithivraj Govindaraj,Cesar Rendon,Deepak Samuel,Michael Tytgat
2024-01-14
Abstract:Muon radiography often referred to as muography, is an imaging technique that uses freely available cosmic-ray muons to study the interior structure of natural or man-made large-scale objects. The amount of multidisciplinary applications of this technique keeps increasing over time and a variety of basic detector types have already been used in the construction of muon telescopes. Here, we are investigating the use of advanced gaseous detectors for muography. As our basic solution, given its robustness and ease of operation in remote, outdoor environments, a scintillator-based muon telescope with silicon photomultiplier readout is being developed. To enhance the telescope performance, we are proposing the use of Multi-gap Resistive Plate Chambers (mRPCs) and Thick Gas Electron Multipliers (THGEMs). While the former offer superior time resolution which could be beneficial for detector background rejection, the latter detector type offers excellent spatial resolution, can be manufactured at low cost and operated with a simple gas mixture. Currently, prototype detector planes for each of these proposed types are being designed and constructed, and initial performance tests are in progress. In parallel, a Geant4- based muon telescope simulation is being developed, which will enable us to e.g. optimize our telescope geometry and study the use of superior time resolution for background rejection. The design and status of the three detector prototype planes and the muon telescope, along with the initial results of their performance tests and of the Geant4 simulation studies are reported.
Instrumentation and Detectors,Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the issue of improving detector performance in muon tomography (muography for short). Specifically, the authors explored the use of advanced gas detector technologies to enhance the performance of muon telescopes in order to achieve better time and space resolutions. These improvements are of great significance for reducing background noise, improving image quality, and optimizing the design of muon telescopes. ### Main Research Contents 1. **Basic Solution**: - A scintillator - based muon telescope was developed, with read - out by silicon photomultipliers (SiPMs). This system is robust and easy to operate in remote, outdoor environments, but its time and space resolutions are relatively low. 2. **Advanced Gas Detectors**: - **Multi - gap Resistive Plate Chambers (mRPCs)**: Provide excellent time resolution, which helps in suppressing background noise. - **Thick Gas Electron Multipliers (THGEMs)**: Provide excellent space resolution, are low - cost, and can be operated with simple gas mixtures. ### Specific Research Methods - **Scintillator Detector Prototype**: - Rectangular plastic scintillator bars were used, with dimensions of 56×10×1.4 cm³. - Four BCF - 91A wavelength - shifting fibers were embedded in each scintillator bar and connected to the Hamamatsu S12572 - 010 multi - pixel photon counter (MPPC). - The system was wrapped in a copper one - way mirror film and placed in an aluminum box to reduce noise. - **mRPC Prototype**: - A low - volume, sealed gas chamber was designed, consisting of 7 glass plates, forming 6 gas gaps. - The glass electrodes were manually sprayed with two - component resistive paint, with a coating thickness of about 35 μm. - A 3D - printed polyamide powder frame was used to encapsulate the stack of glass plates to ensure airtightness. - **THGEM Prototype**: - Garfield++ was used for simulation to study the basic layout and performance of THGEM, including hole configuration, gap size, electric field values, and gas mixtures. - Multiple 7×7 cm² THGEM prototypes with different pore diameters and spacings were manufactured for preliminary performance tests. ### Simulation and Experiment - **Geant4 Simulation**: - A four - plane mRPC muon telescope simulation based on Geant4 was developed to optimize the telescope geometry and study the role of time resolution in suppressing background noise. - The simulation results show that a 20 - cm plane spacing can provide a time difference of about 0.5 ns. - **Preliminary Experimental Results**: - The THGEM prototype was preliminarily tested for performance using the AMPTEK Mini - X X - ray tube to verify the detector's stability, efficiency, and gain. ### Conclusions and Prospects By combining scintillator and advanced gas detector technologies, the authors aim to develop a high - performance muon telescope that can perform well in both time and space resolutions. In addition, optimizing gas consumption is also an important consideration in the design to meet the application requirements of remote muon tomography. Future work will continue to optimize the detector design, conduct more detailed performance tests, and explore the use of environmentally - friendly gas mixtures.