Cryogenic Focus Measurement System for a Wide-Field Infrared Space Telescope

Samuel S. Condon,Stephen Padin,James Bock,Howard Hui,Phillip Korngut,Chi Nguyen,Jordan Otsby
DOI: https://doi.org/10.1364/AO.514784
2024-10-20
Abstract:We describe a technique for measuring focus errors in a cryogenic, wide-field, near-infrared space telescope. The measurements are made with a collimator looking through a large vacuum window, with a reflective cold filter to reduce background thermal infrared loading on the detectors and optics. The vacuum window and cold filter introduce wavefront error which we characterize using an autocollimating microscope. For the $200\textrm{ mm}$ diameter aperture $f/3$ space telescope, SPHEREx, we achieve a focus position measurement with a $\sim15 \textrm{ }\mu \textrm{m systematic}$ and a $\sim 5\textrm{ }\mu \textrm{m statistical}$ error.
Instrumentation and Methods for Astrophysics,Optics
What problem does this paper attempt to address?
### What problems does this paper attempt to solve? This paper aims to solve the problem of focus measurement in low - temperature, wide - angle, near - infrared space telescopes (such as SPHEREx) in a low - temperature environment. Specifically, the article describes a technique for measuring the focal length error of low - temperature, wide - angle, near - infrared space telescopes. This technique passes a collimator through a large vacuum window and uses a reflective cold filter to reduce the impact of background thermal infrared radiation on detectors and optical components. #### Main problems: 1. **Focus measurement in a low - temperature environment**: Since low temperatures can cause mechanical deformation and affect the focus position of the telescope, it is necessary to perform accurate focus measurement on the ground after cooling the telescope to the operating temperature (60 K). 2. **Challenges for large - field - of - view telescopes**: The SPHEREx telescope has a relatively large field of view (11.3°×3.5°), which results in very large vacuum windows and cold filters, increasing the measurement difficulty. 3. **Introduction of wave - front errors**: Vacuum windows and cold filters will introduce wave - front errors, and these errors will affect the accuracy of focus measurement and need to be characterized and corrected in detail. #### Solutions: - **Collimator configuration**: Use a collimator to inject a light beam into the telescope through the vacuum window, and use a self - collimating microscope to measure the focus position. - **Cold filter design**: Adopt a gold - plated sapphire cold filter to reduce the impact of laboratory background thermal radiation on the detector. - **Wave - front error correction**: Measure the wave - front error by a self - collimating microscope and correct the wave - front error by methods such as Hartmann Mask. - **Multiple - round measurement and adjustment**: Through multiple measurements and adjustments of the detector position (using shims), gradually optimize the focus performance until the requirements are met. #### Experimental results: - For the SPHEREx telescope, a focus measurement accuracy of about 15 µm in systematic error and about 5 µm in statistical error has been achieved. - The focus measurement results show that after the vibration test, the focus position has no obvious change, which proves the stability of the system. ### Formula summary: The formulas involved in the article are as follows: 1. **Focus error calculation formula**: \[ dZ = (\zeta_{\text{tel}} - \zeta_{\text{col}}) \left(\frac{f_{\text{tel}}}{f_{\text{col}}}\right)^2 \] where: - \( dZ \) is the focus error of the telescope, - \( \zeta_{\text{tel}} \) is the point - source position that minimizes the spot area at the focus of the telescope, - \( \zeta_{\text{col}} \) is the point - source position at the focus of the collimator, - \( f_{\text{tel}} \) and \( f_{\text{col}} \) are the focal lengths of the telescope and the collimator respectively. 2. **Lateral magnification**: \[ m = \frac{f_{\text{col}}}{f_{\text{tel}}} \] 3. **Longitudinal magnification**: \[ m^2=\left(\frac{2.54}{0.6}\right)^2\approx18 \] Through these techniques and methods, the research team has successfully solved the problem of focus measurement of wide - angle near - infrared space telescopes in a low - temperature environment, providing technical support for subsequent space observation tasks.