Calibrating VLBI Polarization Data Using GPCAL. I. Frequency-Dependent Calibration

Jongho Park,Keiichi Asada,Do-Young Byun
2023-10-05
Abstract:In this series of papers, we present new methods of frequency- and time-dependent instrumental polarization calibration for Very Long Baseline Interferometry (VLBI). In most existing calibration tools and pipelines, it has been assumed that instrumental polarization is constant over frequency within the instrument bandwidth and over time. The assumption is not always true and may prevent an accurate calibration, which can result in degradation of the quality of linear polarization images. In this paper, we present a method of frequency-dependent instrumental polarization calibration that is implemented in GPCAL, a recently developed polarization calibration pipeline. The method is tested using simulated data sets generated from real Very Long Baseline Array (VLBA) data. We present the results of appyling the method to real VLBA data sets observed at 15 and 43 GHz. We were able to eliminate significant variability in cross-hand visibilities over frequency that is caused by frequency-dependent instrumental polarization. As a result of the calibration, linear polarization images were slightly to modestly improved as compared to those obtained without frequency-dependent instrumental polarization calibration. We discuss the reason for the minor impact of frequency-dependent instrumental polarization calibration on existing VLBA data sets and prospects for applying the method to future VLBI data sets, which are expected to provide very large bandwidths.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: in very long baseline interferometry (VLBI), the inaccurate calibration problem caused by the change of the instrument polarization response with frequency and time. Specifically, most of the existing calibration tools and procedures assume that the instrument polarization is constant throughout the observation bandwidth and time, but this assumption is not always valid and may lead to a decline in the quality of the linear polarization image. ### Specific description of the problem 1. **Frequency - dependent polarization calibration**: - Existing calibration methods usually assume that the instrument polarization is constant within the observation bandwidth, which is not always true in actual operation. - Frequency - dependent polarization leakage (D - terms) can cause significant changes in cross - hand visibilities at different frequencies, thus affecting the quality of the linear polarization image. 2. **Time - dependent polarization calibration**: - Polarization leakage not only changes with frequency but may also change with time, especially in large - telescope and high - frequency - band observations, where antenna pointing errors will be more severe. - Time - dependent polarization leakage also needs to be corrected to improve the quality of the data. ### Solutions To address the above problems, the author proposes two new calibration methods: 1. **Frequency - dependent polarization calibration**: - Use GPCAL (Generalized Polarization CALibration pipeline) to achieve frequency - dependent polarization calibration. - The effectiveness of this method has been verified through a simulated data set and applied to the real VLBA (Very Long Baseline Array) observation data. 2. **Time - dependent polarization calibration**: - In another accompanying paper, the author describes how to correct the time - varying polarization leakage. ### Application and effect of the methods - **Verification with simulated data**: By generating a simulated data set based on the real VLBA data, the effectiveness of the new method in correcting frequency - dependent polarization leakage has been verified. - **Application to real data**: The new method has been applied to the real VLBA observation data at 15 GHz and 43 GHz. The results show that the quality of the linear polarization image after correction has been improved, especially in dealing with frequency - dependent polarization leakage. ### Conclusion These new calibration methods can significantly improve the calibration accuracy of VLBI data. Especially when dealing with frequency - dependent and time - dependent polarization leakage, they can effectively improve the quality of the linear polarization image. This is of great significance for future VLBI observations, especially those providing very wide - bandwidth data sets. --- If you need more detailed formula derivations or specific technical details, please let me know and I will further explain for you.