Quantum metrology in a lossless Mach-Zehnder interferometer using entangled photon inputs

Shreyas Sadugol,Lev Kaplan
DOI: https://doi.org/10.1116/5.0137125
2023-10-03
Abstract:Using multi-photon entangled input states, we estimate the phase uncertainty in a noiseless Mach-Zehnder interferometer (MZI) using photon-counting detection. We assume a flat prior uncertainty and use Bayesian inference to construct a posterior uncertainty. By minimizing the posterior variance to get the optimal input states, we first devise an estimation and measurement strategy that yields the lowest phase uncertainty for a single measurement. N00N and Gaussian states are determined to be optimal in certain regimes. We then generalize to a sequence of repeated measurements, using non-adaptive and fully adaptive measurements. N00N and Gaussian input states are close to optimal in these cases as well, and optimal analytical formulae are developed. Using these formulae as inputs, a general scaling formula is obtained, which shows how many shots it would take on average to reduce phase uncertainty to a target level. Finally, these theoretical results are compared with a Monte Carlo simulation using frequentist inference. In both methods of inference, the local non-adaptive method is shown to be the most effective practical method to reduce phase uncertainty.
Quantum Physics
What problem does this paper attempt to address?
### Problems Addressed by the Paper The paper aims to investigate the problem of quantum metrology using entangled photon inputs in a lossless Mach-Zehnder Interferometer (MZI). Specifically, the goals of the paper include: 1. **Phase Uncertainty Estimation**: - Estimating phase uncertainty in a lossless Mach-Zehnder Interferometer using photon counting detection with multi-photon entangled states. - Assuming the prior uncertainty of the phase is uniformly distributed and using Bayesian inference to construct the posterior uncertainty. 2. **Optimal Measurement Strategy**: - Determining the optimal input state by minimizing the posterior variance to achieve the lowest phase uncertainty in a single measurement. - Identifying that in certain cases, N00N states and Gaussian states are optimal. 3. **Extension to Multiple Measurements**: - Extending single measurement to multiple repeated measurements using non-adaptive and fully adaptive measurement methods. - Developing analytical formulas suitable for multiple measurements and obtaining a general scaling formula to predict the average number of measurements needed to reduce phase uncertainty to a target level. 4. **Comparison of Theory and Simulation**: - Comparing these theoretical results with Monte Carlo simulations based on frequency inference. - Demonstrating that among the two inference methods, the local non-adaptive method is the most effective practical method for reducing phase uncertainty. Through these studies, the paper aims to improve the accuracy of quantum metrology techniques in various applications, particularly in fields such as biological systems, gravitational wave detection, and atomic clocks.