Production and validation of industrially produced large-sized GEM foils for the Phase-2 upgrade of the CMS muon spectrometer

Inseok Yoon
DOI: https://doi.org/10.1016/j.nima.2023.168723
2023-09-28
Abstract:The upgrade of the CMS detector for the high luminosity LHC (HL-LHC) will include gas electron multiplier (GEM) detectors in the end-cap muon spectrometer. Due to the limited supply of large area GEM detectors, the Korean CMS (KCMS) collaboration had formed a consortium with Mecaro Co., Ltd. to serve as a supplier of GEM foils with area of approximately $0.6\,m^{2}$. The consortium has developed a double-mask etching technique for production of these large-sized GEM foils. This article describes the production, quality control, and quality assessment (QA/QC) procedures and the mass production status for the GEM foils. Validation procedures indicate that the structure of the Korean foils are in the designed range. Detectors employing the Korean foils satisfy the requirements of the HL-LHC in terms of the effective gain, response uniformity, rate capability, discharge probability, and hardness against discharges. No aging phenomena were observed with a charge collection of $82\,mC/cm^{2}$. Mass production of KCMS GEM foils is currently in progress.
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to produce and verify the quality and performance of large - scale industrially - produced GEM (Gas Electron Multiplier) foils in the second - phase upgrade of the CMS muon spectrometer at the High - Luminosity Large Hadron Collider (HL - LHC). Specifically, the Korea CMS (KCMS) team, in cooperation with Mecaro Company, has developed a double - mask etching technique to produce these large GEM foils to meet the requirements of the CMS experiment. The paper describes in detail the production process, quality control and quality assessment procedures of GEM foils, as well as the current status of large - scale production. Through these efforts, the research team hopes to ensure that the produced GEM foils can meet the requirements of HL - LHC in terms of effective gain, response uniformity, rate capability, discharge probability and anti - discharge capability, and no aging phenomenon occurs. ### Main Concerns: 1. **Production Technology**: A new double - mask etching technique has been developed for the production of large GEM foils. This method is simpler and faster than the traditional single - mask technique. 2. **Quality Control**: The quality of GEM foils is ensured through methods such as optical inspection, leakage current measurement and long - term voltage test. 3. **Performance Verification**: The effective gain, response uniformity, rate capability, discharge probability and anti - discharge capability of GEM foils are tested and verified in detail using the CMS GE1/1 short - type detector. 4. **Aging Test**: The stability and reliability of GEM foils under high cumulative charge are verified through long - time charge - discharge tests. ### Key Indicators: - **Effective Gain**: The effective gain of GEM foils is measured, and the result is consistent with that of GEM foils produced by CERN. - **Response Uniformity**: The response uniformity of the detector is ensured by measuring the responses in different regions. - **Rate Capability**: The performance of GEM foils under high particle flux is tested, and the result shows that its performance is comparable to that of GEM foils produced by CERN. - **Discharge Probability**: Through the induced - discharge experiment, it is verified that the discharge probability of GEM foils is low, and there is no obvious performance degradation after discharge. - **Anti - Aging Capability**: Through long - time charge - discharge tests, it is confirmed that there is no aging phenomenon in GEM foils under high cumulative charge. ### Conclusion: The paper shows that the Korean GEM foils produced by the double - mask etching technique meet the requirements of HL - LHC in terms of performance and can be used for the upgrade of the CMS muon spectrometer. These foils perform excellently in terms of effective gain, response uniformity, rate capability, discharge probability and anti - discharge capability, and have good anti - aging ability. This provides a reliable basis for future large - scale production and application.