Photon noise correlations in millimeter-wave telescopes

Charles A. Hill,Akito Kusaka
DOI: https://doi.org/10.1364/AO.504979
2023-09-03
Abstract:Many modern millimeter and submillimeter (``mm-wave'') telescopes for astronomy are deploying more detectors by increasing detector pixel density, and with the rise of lithographed detector architectures and high-throughput readout techniques, it is becoming increasingly practical to overfill the focal plane. However, when the pixel pitch $p_{\rm pix}$ is small compared to the product of the wavelength $\lambda$ and the focal ratio $F$, or $p_{\mathrm{pix}} \lesssim 1.2 F \lambda$, the Bose term of the photon noise correlates between neighboring detector pixels due to the Hanbury Brown & Twiss (HBT) effect. When this HBT effect is non-negligible, the array-averaged sensitivity scales with detector count $N_{\mathrm{det}}$ less favorably than the uncorrelated limit of $N_{\mathrm{det}}^{-1/2}$. In this paper, we present a general prescription to calculate this HBT correlation based on a quantum optics formalism and extend it to polarization-sensitive detectors. We then estimate the impact of HBT correlations on the sensitivity of a model mm-wave telescope and discuss the implications for focal-plane design.
Instrumentation and Methods for Astrophysics,Optics
What problem does this paper attempt to address?
### What problem does this paper attempt to solve? This paper aims to solve the problem of photon - noise correlation caused by high - pixel density in millimeter - wave (mm - wave) telescopes. Specifically, with the increase in the pixel density of detectors in modern millimeter - wave and sub - millimeter - wave telescopes, the photon - noise correlation between adjacent detectors becomes significant, which will have an adverse impact on the sensitivity of the telescope. #### Main problems 1. **Photon - noise correlation**: When the pixel pitch \( p_{\text{pix}} \) is less than or close to \( 1.2F\lambda \) (where \( F \) is the effective focal ratio and \( \lambda \) is the operating wavelength), the photon - noise between adjacent detector pixels will be correlated due to the Hanbury Brown & Twiss (HBT) effect. This correlation will lead to a decrease in the average sensitivity of the array, and the degree of decrease is not as much as \( N^{-1/2}_{\text{det}} \) (where \( N_{\text{det}} \) is the number of detectors) in the uncorrelated case. 2. **Sensitivity optimization**: The paper calculates this HBT correlation through the quantum - optical formalization method and extends it to polarization - sensitive detectors. Then, it estimates the impact of HBT correlation on the sensitivity of the model millimeter - wave telescope and discusses the significance for the focal - plane design. 3. **Impact on experimental design**: The research results have an important impact on the design of millimeter - wave detector arrays, especially in terms of pixel - size optimization and mapping speed. #### Specific content - **Theoretical basis**: Based on the circuit formalization method of thermal - photon correlation in quantum detectors proposed by Zmuidzinas, a theoretical framework for dealing with the HBT effect is established. - **Model optical system**: A model optical system is defined to estimate the impact of HBT correlation on sensitivity. - **Correlation calculation**: The expression of intensity correlation is derived, and the polarization mode is considered. - **Sensitivity impact**: The impact of HBT correlation on the sensitivity, mapping speed, and pixel - size optimization of the telescope system is discussed. - **Implication for experimental design**: How to optimize sensitivity when designing millimeter - wave detector arrays is explored. ### Conclusion Through detailed theoretical analysis and model calculations, the paper reveals the impact of photon - noise correlation on sensitivity in high - pixel - density millimeter - wave telescopes and provides an important reference for future telescope designs. In particular, when the pixel pitch is small, special attention needs to be paid to the HBT effect to ensure the best sensitivity performance.