The realisation of fast X-ray computed tomography using a limited number of projection images for dimensional metrology

Wenjuan Sun,Stephan Chretien,Ander Biguri,Manuchehr Soleimani,Thomas Blumensath,Jessica Talbott
DOI: https://doi.org/10.1016/j.ndteint.2023.102852
2023-05-17
Abstract:Due to the merit of establishing volumetric data, X-ray computed tomography (XCT) is increasingly used as a non-destructive evaluation technique in the quality control of advanced manufactured parts with complex non-line-of-sight features. However, the cost of measurement time and data storage hampers the adoption of the technique in production lines. Commercial fast XCT utilises X-ray detectors with fast detection capability, which can be expensive and results a large amount of data. This paper discussed a different approach, where fast XCT was realised via the acquisition of a small number of projection images instead of full projection images. An established total variation (TV) algorithm was used to handle the reconstruction. The paper investigates the feasibility of using the TV algorithm in handling a significantly reduced number of projection images for reconstruction. This allows a reduction of measurement time from fifty-two minutes to one minute for a typical industrial XCT system. It also enables a reduction of data size proportionally. A test strategy including both quantitative and qualitative test metrics was considered to evaluate the effectiveness of the reconstruction algorithm. The qualitative evaluation includes both the signal to noise ratio and the contrast to noise ratio. The quantitative evaluation was established using reference samples with different internal and external geometries. Simulation data were used in the assessment considering various influence factors, such as X-ray source property and instrument noise. The results demonstrated the possibility of using advanced reconstruction algorithms in handling XCT measurements with a significantly limited number of projection images for dimensional measurements.
Applied Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to reduce the measurement time and the amount of data storage by reducing the number of projection images when using fast X - ray computed tomography (XCT) for dimensional measurement in industrial applications. Specifically, the paper explores the possibility of using the Total Variation (TV) algorithm to achieve fast XCT with a limited number of projection images, reducing the measurement time from 52 minutes to 1 minute and correspondingly reducing the amount of data. This method does not require any modification or enhancement to existing equipment, thus providing an economical and efficient solution. ### Background and Problem Description X - ray computed tomography (XCT) is increasingly used for quality control of advanced manufacturing parts with complex non - line - of - sight features because of its advantage of being able to establish volume data. However, the costs of measurement time and data storage limit its wide application on the production line. Traditional fast XCT methods rely on high - speed X - ray detectors, which are not only expensive but also generate a large amount of data. ### Solution The paper proposes a different method, that is, to achieve fast XCT by collecting a small number of projection images instead of full - projection images. The established Total Variation (TV) algorithm is used in the study to deal with the reconstruction problem. This method allows the measurement time to be reduced from 52 minutes to 1 minute, and the amount of data is also correspondingly reduced. ### Research Method In order to evaluate the effectiveness of the TV algorithm when dealing with a significantly reduced number of projection images, the paper designs a test strategy including qualitative and quantitative test indicators. Qualitative evaluation includes signal - to - noise ratio (SNR) and contrast - to - noise ratio (CNR), and quantitative evaluation is based on reference samples with different internal and external geometries. In addition, various influencing factors such as X - ray source characteristics and instrument noise are also considered using simulated data. ### Main Results The research results show that using advanced reconstruction algorithms (especially the TV algorithm) can handle XCT measurements with a significantly reduced number of projection images, thus achieving fast scanning. Although the reconstruction time is still relatively long, the paper discusses several improvement methods. The experimental results show that the OS - ASD - POCS algorithm performs better than the OS - SART algorithm when dealing with a limited number of projection images, especially in terms of image quality and edge preservation. ### Conclusion This paper lays the foundation for fast XCT measurement without changing or enhancing existing equipment, demonstrating the feasibility of using the TV algorithm to process a limited number of projection images. Although the current reconstruction time is relatively long, this method provides a feasible path for fast XCT measurement in industrial applications.