Towards a large-area RPWELL detector: design optimization and performance

D. Zavazieva,L. Moleri,A. Jash,G. Sela,F. de Vito-Halevy,S. Bressler
2023-07-18
Abstract:We present a new design and assembly procedure of a large-area gas-avalanche Resistive-Plate WELL (RPWELL) detector. A $50\times50 ~\mathrm{cm^2}$ prototype was tested in $\mathrm{80 ~GeV/c}$ muon beam at CERN-SPS, presenting improved performances compared to previous ones: MIP detection efficiency over 96\% with 3\% uniformity across the entire detector area, a charge gain of $\mathrm{\approx{7.5 \times 10^3}}$ with a uniformity of 22\%, and discharge probability below $\mathrm{10^{-6}}$ with a few single hotspots attributed to production imperfections. These results pave the way towards further up-scaling detectors of this kind.
Instrumentation and Detectors
What problem does this paper attempt to address?
This paper aims to solve the key problems in the design and assembly process of large - scale gaseous avalanche resistive plate well (RPWELL) detectors, especially how to realize the large - area of the detector while maintaining high detection efficiency, uniform gain and low discharge probability. Specifically, the paper attempts to solve the following main problems: 1. **Design and Manufacture of Large - Area Detectors**: How to enlarge the size of RPWELL detectors without sacrificing performance. This involves multiple aspects such as material selection, manufacturing process and assembly technology. 2. **Performance Optimization**: - **Detection Efficiency**: How to improve and maintain the minimum ionizing particle (MIP) detection efficiency in the entire detector area. - **Gain Uniformity**: How to reduce the non - uniformity of gain, especially in large - area detectors. - **Discharge Probability**: How to reduce the probability of discharge during the operation of the detector, especially under high - flux conditions. 3. **Technical Challenges**: - **Uneven Electrode Thickness**: How to control the thickness of electrodes to reduce the non - uniformity of gain. - **Glue Penetration**: How to prevent glue from penetrating into the THWELL holes, thereby avoiding the occurrence of electrical instability. To achieve these goals, the author proposes a new design and assembly method and verifies its effectiveness through experiments. Specific improvement measures include: - **Strict Electrode Selection Criteria**: The allowable deviation range of electrode thickness is + 0 / - 5% to ensure the uniformity of electrode thickness. - **Dedicated Bonding Points**: Use glue only at specific positions to prevent glue from spreading into the THWELL holes. - **Improved Grounding Technique**: By optimizing the grounding method, reduce the vertical linear low - efficiency mode. Finally, through the tests carried out on the CERN - SPS beam line, this 50×50 cm² RPWELL prototype exhibits the following performance: - The detection efficiency exceeds 96%, and the uniformity in the entire detector area reaches 3%. - The gain is approximately \( 7.5\times10^3 \), and the uniformity is 22%. - The discharge probability is lower than \( 10^{-6} \), and only a few hot - spot areas have a slightly higher discharge probability. These results provide an important reference and basis for further expanding the size of RPWELL detectors in the future.