Mechanical photoluminescence excitation spectra of a strongly driven spin-mechanical system

Xinzhu Li,Hailin Wang
2023-04-08
Abstract:We report experimental studies of a driven spin-mechanical system, in which a nitrogen vacancy (NV) center couples to out-of-plane vibrations of a diamond cantilever through the excited-state deformation potential. Photoluminescence excitation studies show that in the unresolved sideband regime and under strong resonant mechanical driving, the excitation spectra of a NV optical transition feature two spectrally sharp peaks, corresponding to the two turning points of the oscillating cantilever. In the limit that the strain-induced frequency separation between the two peaks far exceeds the NV zero-phonon linewidth, the spectral position of the individual peak becomes sensitive to minute detuning between the mechanical resonance and the external driving force. For a fixed optical excitation frequency near the NV transition, NV fluorescence as a function of mechanical detuning features resonances with a linewidth that can be orders of magnitude smaller than the intrinsic linewidth of the mechanical mode. This enhanced sensitivity to mechanical detuning can potentially provide an effective mechanism for mechanical sensing, for example, mass sensing via measurements of induced changes in the mechanical oscillator frequency.
Mesoscale and Nanoscale Physics,Quantum Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: in a strongly - driven spin - mechanical system, how does the coupling between the nitrogen - vacancy (NV) center and the vibration of the diamond cantilever affect the photoluminescence excitation (PLE) spectrum, and explore the potential applications of such a system in mechanical sensing. Specifically, the authors studied the influence of strong resonant mechanical driving on the excitation spectrum of NV optical transitions when the NV center is coupled to the out - of - plane vibration of the diamond cantilever through the excited - state deformation potential in the unresolved sideband regime. It was found that in this case, the excitation spectrum exhibits two spectrally very sharp peaks, corresponding to the two turning points of the oscillating cantilever. When the strain - induced frequency separation is much larger than the NV zero - phonon linewidth, the spectral position of a single peak is very sensitive to the small detuning between the mechanical resonance and the external driving force. This enables the NV fluorescence as a function of mechanical detuning to exhibit resonances with extremely narrow linewidths, and the linewidths of these resonances can be several orders of magnitude smaller than the intrinsic linewidth of the mechanical mode. This enhanced sensitivity to mechanical detuning provides an effective mechanism for mechanical sensing, for example, mass sensing by measuring the induced frequency change of the mechanical oscillator. Therefore, this study aims to develop a new, highly sensitive mechanical sensing method, using the fluorescence characteristics of the NV center to detect small mass changes or changes in other physical quantities. ### Key Formulas 1. **Electron - phonon interaction Hamiltonian**: \[ V(t) = D\sin(\omega_mt+\phi)\vert e\rangle\langle e\vert \] where \(D\) is the deformation potential, \(\omega_m\) is the mechanical vibration frequency, and \(\phi\) is the phase. 2. **Excited - state population**: \[ \rho_{ee}(\omega)\propto\sum_{n = -\infty}^{\infty}J_n^2(A)\frac{\gamma/ 2}{(\omega-\omega_0 - n\omega_m)^2+(\gamma/ 2)^2} \] where \(J_n(x)\) is the first - kind Bessel function, \(A\) is the dimensionless driving amplitude, \(\gamma\) is the zero - phonon linewidth, and \(\omega_0\) is the zero - phonon line resonance frequency. 3. **mPLE resonance linewidth**: \[ \gamma_{\text{mPLE}}\approx\left|\frac{ds}{d\delta}\right|\gamma\big|_{\delta = \delta_0} \] where \(s\) is the spectral position of the NV optical transition, \(\delta\) is the mechanical detuning, and \(\delta_0\) is the detuning value at the center of the mPLE resonance. 4. **Sensitivity of frequency - shift measurement**: \[ \eta=\left|\frac{dF}{d\delta}\right|\sigma_s^{-1} \] where \(F\) is the interference fringe contrast, and \(\sigma_s\) is the contrast uncertainty at an average time of 1 second. Through these studies, the authors demonstrated the unique behavior of the NV center under strong mechanical driving and its potential application in high - precision mechanical sensing.