Femtosecond laser induced breakdown spectroscopy based standoff detection of explosives and discrimination using principal component analysis.

Hamad Syed,A. K. Shaik,Venugopal Rao Soma,Chandu Byram,Nageswara Rao Epuru
DOI: https://doi.org/10.1364/OE.26.008069
IF: 3.8
2018-04-02
Optics Express
Abstract:We report the standoff (up to ~2 m) and remote (~8.5 m) detection of novel high energy materials/explosive molecules (Nitroimidazoles and Nitropyrazoles) using the technique of femtosecond laser induced breakdown spectroscopy (LIBS). We utilized two different collection systems (a) ME-OCT-0007 (commercially available) and (b) Schmidt-Cassegrain telescope for these experiments. In conjunction with LIBS data, principal component analysis was employed to discriminate/classify the explosives and the obtained results in both configurations are compared. Different aspects influencing the LIBS signal strength at far distances such as fluence at target, efficiency of collection system etc. are discussed.
Materials Science,Physics,Engineering,Medicine,Chemistry
What problem does this paper attempt to address?