Hybrid clustering system using Nystagmus parameters discrimination for vestibular disorder diagnosis.

A. Mouelhi,Hedi Trabelsi,Hanene Sahli,J. Marrakchi,M. Sayadi,A. B. Slama,S. Boukriba
DOI: https://doi.org/10.3233/XST-200661
2020-07-31
Journal of X-Ray Science and Technology
Abstract:BACKGROUD AND OBJECTIVE The control of clinical manifestation of vestibular system relies on an optimal diagnosis. This study aims to develop and test a new automated diagnostic scheme for vestibular disorder recognition. METHODS In this study we stratify the Ellipse-fitting technique using the Video Nysta Gmographic (VNG) sequence to obtain the segmented pupil region. Furthermore, the proposed methodology enabled us to select the most optimum VNG features to effectively conduct quantitative evaluation of nystagmus signal. The proposed scheme using a multilayer neural network classifier (MNN) was tested using a dataset involving 98 patients affected by VD and 41 normal subjects. RESULTS The new MNN scheme uses only five temporal and frequency parameters selected out of initial thirteen parameters. The scheme generated results reached 94% of classification accuracy. CONCLUSIONS The developed expert system is promising in solving the problem of VNG analysis and achieving accurate results of vestibular disorder recognition or diagnosis comparing to other methods or classifiers.
Computer Science,Medicine,Engineering
What problem does this paper attempt to address?