High-resolution single-shot spiral diffusion-weighted imaging at 7T using expanded encoding with compressed sensing

Gabriel Varela-Mattatall,Paul I. Dubovan,Tales Santini,Kyle M. Gilbert,Ravi S. Menon,Corey A. Baron
2022-11-15
Abstract:Purpose: The expanded encoding model incorporates spatially- and time-varying field perturbations for correction during reconstruction. So far, these reconstructions have used the conjugate gradient method with early stopping used as implicit regularization. However, this approach is likely suboptimal for low-SNR cases like diffusion or high-resolution MRI. Here, we investigate the extent that l1-wavelet regularization, or equivalently compressed sensing (CS), combined with expanded encoding improves trade-offs between spatial resolution, readout time and SNR for single-shot spiral diffusion-weighted imaging at 7T. The reconstructions were performed using our open-source GPU-enabled reconstruction toolbox, MatMRI, that allows inclusion of the different components of the expanded encoding model, with or without CS. Methods: In vivo accelerated single-shot spirals were acquired with five acceleration factors (2-6) and three in-plane spatial resolutions (1.5, 1.3, and 1.1 mm). From the in vivo reconstructions, we estimated diffusion tensors and computed fractional anisotropy maps. Then, simulations were used to quantitatively investigate and validate the impact of CS-based regularization on image quality when compared to a known ground truth. Results: In vivo reconstructions revealed improved image quality with retainment of small features when CS was used. Simulations showed that the joint use of the expanded encoding model and CS improves accuracy of image reconstructions (reduced mean-squared error) over the range of acceleration factors investigated. Conclusion: The expanded encoding model and CS regularization are complementary tools for single-shot spiral diffusion MRI, which enables both higher spatial resolutions and higher acceleration factors.
Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the improvement of image quality in single - shot spiral diffusion - weighted imaging (DWI) under high - resolution and accelerated acquisition conditions in 7 - Tesla (7T) magnetic resonance imaging (MRI). Specifically, the author explores how to optimize the reconstruction process of single - shot spiral diffusion - weighted imaging by combining the expanded encoding model and compressed sensing (CS) techniques, so as to improve the signal - to - noise ratio (SNR), reduce image artifacts, and achieve a higher acceleration factor while maintaining high spatial resolution. ### Background and Challenges In high - field - strength MRI, such as 7T, due to the influence of magnetic field inhomogeneity and eddy current effects, single - shot spiral diffusion - weighted imaging is prone to various artifacts, such as ghosting, blurring, and geometric distortion. These problems are particularly serious under high - resolution and accelerated acquisition conditions because these conditions will increase phase errors and eddy current effects, thereby degrading image quality. ### Solutions 1. **Expanded Encoding Model**: - The expanded encoding model compensates for artifacts caused by magnetic field inhomogeneity and eddy current effects during the imaging process by introducing a magnetic field perturbation correction term that varies in space and time. - This model includes static field offset (compensated by B0 map) and dynamic field changes (characterized by real - time monitoring and fitting spherical harmonic functions). 2. **Compressed Sensing (CS)**: - Compressed sensing is a reconstruction technique that utilizes signal sparsity and can effectively reduce noise amplification and artifacts. - By adding an ℓ1 - wavelet regularization term in the reconstruction process, the image quality and SNR can be further improved. ### Research Methods - **Data Acquisition**: - In - vivo experiments were carried out on a 7T MRI scanner to collect single - shot spiral diffusion - weighted imaging data with different acceleration factors (2 - 6 times) and different in - plane spatial resolutions (1.5, 1.3, 1.1 mm). - The MatMRI toolbox was used for reconstruction, which supports the expanded encoding model and compressed sensing techniques. - **Simulation Experiments**: - K - space data was generated by simulation and different levels of noise were added to evaluate the performance of the reconstruction method under different SNR conditions. - Evaluation metrics include the normalized root - mean - square error (NRMSE) and the quality of the fractional anisotropy (FA) map. ### Results - **In - vivo Experiments**: - The results show that the quality of the reconstructed images using compressed sensing techniques is significantly improved, especially under low - SNR conditions. - The integrity of the fractional anisotropy (FA) map is better preserved after using compressed sensing techniques. - **Simulation Experiments**: - The simulation results show that the combined use of the expanded encoding model and compressed sensing techniques can significantly reduce the reconstruction error and improve the image quality. - Under different acceleration factors and the number of virtual coils, the compressed sensing technique shows better performance than the traditional least - squares method (LS). ### Conclusions The expanded encoding model and compressed sensing techniques are complementary tools that can effectively improve the image quality of single - shot spiral diffusion - weighted imaging in 7T MRI. These techniques not only improve the spatial resolution and SNR but also make higher acceleration factors possible, thereby shortening the imaging time and improving the feasibility of clinical applications.