An Integrated Biological Optimization framework for proton SBRT FLASH treatment planning allows dose, dose rate, and LET optimization using patient-specific ridge filters

Ruirui Liu,Serdar Charyyev,Niklas Wahl,Wei Liu,Minglei Kang,Jun Zhou,Xiaofeng Yang,Filipa Baltazar,Martina Palkowitsch,Kristin Higgins,William Dynan,Jeffrey Bradley,Liyong Lin
DOI: https://doi.org/10.48550/arXiv.2207.08016
2022-07-17
Abstract:Purpose: Patient-specific ridge filters can modulate proton energy to obtain a conformal dose. We describe a new framework for optimization of filter design and spot maps to meet the unique demands of FLASH radiotherapy. We demonstrate an Integrated Biological Optimization IMPT (IBO-IMPT) approach for optimization of dose, dose-averaged dose rate (DADR), and dose-averaged LET (LETd). Methods: We developed inverse planning software to design patient-specific ridge filters that spread the Bragg peak from a fixed-energy, 250 MeV beam to a proximal beam-specific planning target volume. The software optimizes patient-specific ridge filter and uses a Monte Carlo calculation engine, based on Geant4, to provide dose and LET influence matrices. Plan optimization, using matRAD, accommodates the IBO-IMPT objective function considering dose, dose rate, and LET simultaneously with minimum MU constraints. The framework enables design of both regularly spaced and sparse-optimized ridge filters, which allow faster delivery and selective LET optimization. Volume distributions and histograms for dose, DADR, and LETd are compared using evaluation structures specific to the heart and lung. Results: We used IBO-IMPT to design ridge filters for a central lung tumor patient. The IBO-IMPT framework selectively spared heart and lung by reducing LET and increasing dose rate, relative to IMPT planning. Sparse-optimized ridge filters were superior to regularly spaced ridge filters in dose rate. Together, these innovations substantially increased the DADR in the heart and lung while maintaining good target coverage. The volume that received a FLASH dose rate of higher 40 Gy/second increased by 31% for heart and 50% for lung. Conclusion: This proof-of-concept study demonstrates the feasibility of using an IBO-IMPT framework to accomplish proton FLASH SBPT, accounting for dose, DADR, and LETd simultaneously.
Medical Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to optimize dose, average dose - rate (DADR) and mean linear energy transfer (LETd) through optimizing patient - specific spinal cord filter design and bitmap in ultra - high - speed dose - rate (FLASH) radiotherapy. Specifically, the research aims to develop an integrated biologically - optimized intensity - modulated proton therapy (IBO - IMPT) framework to improve the risk protection of critical organs such as the heart and lungs while maintaining effective coverage and treatment effect on tumors. The main innovation points in the paper include: 1. **Developing the IBO - IMPT framework**: This framework can simultaneously optimize dose, DADR and LETd to achieve the best treatment effect. 2. **Designing patient - specific spinal cord filters**: By using Monte Carlo simulation and inverse planning software, patient - specific spinal cord filters that can adjust proton energy are designed, thereby achieving conformal distribution of dose. 3. **Sparsely optimizing spinal cord filters**: By removing some filter pins, the dose - rate at specific locations is further increased, maximizing the FLASH effect. 4. **Verifying the effectiveness of the method**: Through the treatment plans and dose measurements of actual patients, the feasibility and effectiveness of this method in clinical applications are preliminarily verified. Overall, this research aims to improve the safety and efficacy of FLASH radiotherapy through advanced optimization techniques, especially in terms of protecting critical organs.