Enhanced signature of vacuum birefringence in a plasma wakefield

Feng Wan,Ting Sun,Bai-Fei Shen,Chong Lv,Qian Zhao,Mamutjan Ababekri,Yong-Tao Zhao,Karen Z. Hatsagortsyan,Christoph H. Keitel,Jian-Xing Li
2023-07-26
Abstract:Vacuum birefringence (VB) is a basic phenomenon predicted in quantum electrodynamics (QED). However, due to the smallness of the signal, conventional magnet-based and extremely intense laser-driven detection methods are still very challenging. This is because in the first case the interaction length is large but the field is limited, and vice versa in the second case. We put forward a method to generate and detect VB in a plasma bubble wakefield, which combines both advantages, providing large fields along large interaction lengths. A polarized $\gamma$-photon beam is considered to probe the wakefield along a propagation distance of millimeters to centimeters in the plasma bubble. We find via plasma particle-in-cell simulations that the VB signal in terms of Stokes parameters can reach about $ 10^{-5}$ ($10^{-3}$-$10^{-2}$) for tens of MeV (GeV) probe photons with moderately intense lasers ($10^{20}$-$10^{21}~\mathrm{W/cm^2}$). The main source of noise from plasma electrons is mitigated, in particular, by a choice of $\gamma$-photon polarization and by proper modulation of the plasma density. The proposed method represents an attractive alternative for the experimental observation of VB via laser-plasma interaction.
Plasma Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: How to detect vacuum birefringence (VB), a fundamental phenomenon predicted in quantum electrodynamics (QED), through an efficient and compact method. Specifically, the paper proposes a scheme based on the plasma wakefield. It uses a medium - intensity laser ($10^{20}-10^{21} \, \text{W/cm}^2$) to generate a strong electromagnetic field and measures the VB effect by detecting the propagation of $\gamma$ - photons in the plasma. ### Background problems: 1. **Limitations of traditional methods**: - Traditional methods using static magnetic fields (such as the PVLAS experiment) can provide a relatively large interaction length (from centimeters to meters), but the magnetic field strength is limited (about the Tesla level), resulting in a very weak signal ($\delta\phi \sim 10^{-11} - 10^{-10}$). - Methods driven by ultra - strong lasers can provide extremely large field strengths (about $10^5$ times stronger than laboratory static magnetic fields), but due to the limitation of the laser focal size (a few micrometers), the high - field interaction area is very small, and it is difficult to accumulate sufficient statistical signals. 2. **Research objectives**: - Propose a new method that combines the advantages of large interaction length and strong field to significantly enhance the VB signal. - Ensure that the signal is strong enough to be detected by current experimental techniques, while minimizing the noise interference caused by plasma electrons as much as possible. ### Core problem of the paper: How to design an experimental scheme that can efficiently detect the VB effect of $\gamma$ - photons in the MeV or GeV energy range within an interaction length from millimeters to centimeters? --- ### Formula summary: 1. **Expression of VB signal**: - Phase delay: \[ \delta\phi = \int_0^L dl \frac{2\pi}{\lambda_\gamma} \Delta n(\omega_\gamma) \] - Refractive index difference: \[ \Delta n = n_\parallel - n_\perp \] - In the low - frequency limit, the real part of the refractive index is: \[ \text{Re}[n(\omega_\gamma)] = 1 + \frac{\alpha}{90\pi} \chi_\gamma^2 \left( \frac{4}{7} \right) \] 2. **Field strength in the plasma wakefield**: - Reduced field: \[ E_{\text{red},\perp} = (E + \hat{k} \times B)_\perp \] - Relationship between phase delay and field strength: \[ \delta\phi \propto |E_{\text{red},\perp}|^2 L \] 3. **Noise suppression**: - By selecting the linear polarization direction of $\gamma$ - photons, avoid the circular polarization component introduced by Compton scattering (CS). - Adjust the plasma density to reduce the influence of plasma radiation on the VB signal. --- ### Conclusion: The VB detection method based on the plasma wakefield proposed in the paper has the following advantages: 1. **Combination of strong field and long interaction length**: In an interaction region of 1 centimeter, the effective transverse field strength can reach $10^3 - 10^4 \, \text{T}$, making the VB signal reach the order of $10^{-5} - 10^{-2}$. 2. **Controllable noise**: By reasonably selecting the polarization direction of $\gamma$ - photons and adjusting the plasma density, the noise caused by plasma electrons can be significantly reduced. 3. **Experimental feasibility**: This method can be realized by using currently available laser facilities and has high robustness and stability. Therefore, the main objective of the paper is to propose a new and efficient VB detection method to provide experimental support for verifying the basic predictions of quantum electrodynamics.