An Unusual Case of Renal Artery Stenosis Following Endovascular AAA Repair
M Zanchetta,G Rigatelli,L Pedon,M Zennaro,S Ronsivalle,P Maiolino
DOI: https://doi.org/10.1053/ejvs.2000.1289
IF: 6.427
2001-01-01
European Journal of Vascular and Endovascular Surgery
Abstract:Introduction 14×55 mm were also implanted to cover both common iliac artery aneurysms. Endovascular abdominal aortic aneurysm (AAA) reThe intraoperative and pre-discharge angiograms and computed tomography control showed no enpair seems an effective treatment. Although complications are frequent, secondary radiological doleaks and a patent left renal artery. One month later the patient developed acute renal failure and needed intervention is usually successful. We present an unusual case of ostial renal artery stenosis following a dialysis. An emergency angiogram showed an ostial stenosis of the left renal artery (Fig. 1a). There was no endovascular repair of abdominal aneurysm, without graft misplacement. misplacement of the bifurcated Talent graft and the covered portion of the prosthesis did not cover the vessel. A 6.0×20 mm angioplasty balloon inflated repeatedly to 16 atm was unsuccessful (Fig. 1b). IntraCase Report vascular ultrasonography showed that the stenosis was due to a crease of the aortic intima caused by A 79-year-old woman with a non-functioning right the expansive stress forces of the struts (Fig. 1c). A kidney, due to atherosclerotic occlusion and hyper7×15 mm Corinthian stent (Cordis Europa, Roden, tension, was admitted for treatment of an infrarenal The Netherlands) has been deployed at 10 atm, proAAA. The preoperative angiogram showed an intruding between the open bare wires of the graft (Fig. frarenal AAA classifiable as type II B. Contrast en2b). This resolved the ostial functional stenosis (Fig. hanced CT estimated a maximal diameter of 50 mm 2c). with a proximal neck of 15 mm in length, 20 mm in At 3 months’ follow-up there was no angiographic diameter and a normal distal cuff of 5 mm in length: evidence of restenosis and complete exclusion of the an aneurysm (that is, more than twice the minimum aorto-iliac aneurysms. diameter) of both the common iliac arteries was also present. No calcification or thrombus was noted in the aortic neck. The patient underwent successful imDiscussion plantation of a 24×145 mm, bifurcated Talent graft (Global Medical Manufacturing Corporation, Sunrise, The main complications about the endovascular therFlorida, U.S.A.) with 1 cm of bare stent for suprarenal apy of the abdominal aneurysm are endoleaks, graft fixation. Two AneurX iliac cuffs (Medtronic AVE thrombosis and migration, and iliac artery injuries. Inc., Santa Rosa, California, U.S.A.) of 16×55 mm and Cardiac and pulmonary complications have also been reported. Renal stenosis is an uncommon complication and it usually occurs when the graft is misplaced. ∗ Please address all correspondence to: M. Zanchetta, Via Riva Degli This case was not caused by misplacement of the Ospedali, 35013 Cittadella (PD), Italy. Fax: (39) 049 9424531; E-mail: emodinacit@ulss15.pd.it endoprosthesis but was due to an uncovered strut of