Suction Thrombectomy Use For Right Ventricular Thrombus After Biventricular Support

Modar Alom,Gurjaspreet Bhattal,Mohamed Salih,Mica Alex,Ahmad Kazem,Omar Al-abboud,Nitin Kabra,David Rawitscher,Gregory Milligan,Sameh Sayfo,Timothy George,Aasim Afzal
DOI: https://doi.org/10.1016/j.cardfail.2023.10.336
IF: 6.592
2024-01-01
Journal of Cardiac Failure
Abstract:Background Right ventricular failure is common after left ventricular assist device (LVAD) implantation, especially in patients with pre-existing RV dysfunction. In such cases, a temporary right ventricular assist device (RVAD) may be necessary to support the RV. The Protek Duo cannula with LifeSparc pump is a commonly used configuration for temporary mechanical support, but it can be associated with complications such as thrombus formation and perforation. We report a rare case of Protek Duo cannula thrombus, which was successfully treated with a suction thrombectomy device. Case A 49-year-old female with a history of nonischemic dilated cardiomyopathy and recurrent heart failure hospitalizations was admitted to our facility for cardiogenic shock. Despite initial improvement, her clinical status deteriorated with worsening cardiogenic shock and acute respiratory failure requiring mechanical ventilation. An Impella 5.5 was inserted for temporary LV support. An LVAD workup and evaluation were initiated, but severe RV failure necessitated RV support with an RVAD for hemodynamic optimization before LVAD implantation. Eight days after LVAD implantation, her RV function had improved, and her RVAD was weaned and removed. However, transthoracic echocardiography (TTE) three days after RVAD removal showed a mobile RV mass with a concern for a clot in transit. The patient has been on anticoagulation post LVAD implantation. Decision Making Optimal RV thrombus in Transit management is not well established in the guidelines. Given the high suspicion of thrombus formation and the significant mortality associated with the disease. The patient subsequently underwent a successful RV thrombus suction thrombectomy and was discharged to a rehabilitation facility after a few days. The pathology report came back confirming the presence of an organized thrombus. Conclusion RV thrombus formation is a rare but potential complication of RVAD use, which, if not diagnosed and treated early, can potentially dislodge and lead to a grave outcome such as pulmonary embolism. The presence of a mobile mass or vegetation on a TTE performed post-RVAD removal can help diagnose an RV thrombus. Suction thrombectomy can be used for RV thrombus retrieval to prevent further complications.
cardiac & cardiovascular systems
What problem does this paper attempt to address?