Portable Automatic Microring Resonator System Using a Subwavelength Grating Metamaterial Waveguide for High-Sensitivity Real-Time Optical-Biosensing Applications

Varun Soni,Ching-Wen Chang,Xiaochuan Xu,Chao Wang,Hai Yan,Michael D'Agati,Li-Wei Tu,Quark Yungsung Chen,Huiping Tian,Ray T. Chen,Michael D Agati
DOI: https://doi.org/10.1109/tbme.2020.3029148
IF: 4.6
2021-06-01
IEEE Transactions on Biomedical Engineering
Abstract:The slow light sensor techniques have been applied to bio-related detection in the past decades. However, similar testing-systems are too large to carry to a remote area for diagnosis or point-of-care testing. This study demonstrated a fully automatic portable biosensing system based on the microring resonator. An optical-fiber array mounted on a controller based micro-positioning system, which can be interfaced with MATLAB to locate a tentative position for light source and waveguide coupling alignment. Chip adapter and microfluidic channel could be packaged as a product such that it is cheap to be manufactured and can be disposed of after every test conducted. Thus, the platform can be more easily operated via an ordinary user without expertise in photonics. It is designed based on conventional optical communication wavelength range. The C-band superluminescent-light-emitting-diode light source couples in/out the microring sensor to obtain quasi-TE mode by grating coupler techniques. For keeping a stable chemical binding reaction, the cost-effective microfluidic pump was developed to offer a specific flow rate of 20 μL/min by using a servo-motor, an Arduino board, and a motor driver. The subwavelength grating metamaterial ring resonator shows highly sensitive sensing performance via surface index changes due to biomarker adhered on the sensor. The real-time peak-shift monitoring shows 10 μg/mL streptavidin detection of limit based on the biotin-streptavidin binding reaction. Through the different specific receptors immobilized on the sensor surface, the system can be utilized on the open applications such as heavy metal detection, gas sensing, virus examination, and cancer marker diagnosis.
engineering, biomedical
What problem does this paper attempt to address?
This paper aims to solve the application problems of portable biosensing systems in remote areas or for point - of - care testing. Specifically, traditional biosensing systems are bulky and difficult to be carried to remote areas for diagnosis or on - site testing. Therefore, this paper proposes a fully - automatic portable biosensing system based on microring resonators, which has the following characteristics: 1. **Miniaturization**: By using microring resonators and microfluidic techniques, the system is designed to be small enough to be conveniently carried to any place where it is needed. 2. **Automation**: The system controls the alignment of the fiber array and the micro - positioning system through a MATLAB program, achieving automatic alignment of the light source and waveguide coupling, enabling ordinary users to operate without the need for photonics expertise. 3. **Low cost**: The chip adapter and microfluidic channels can be mass - produced at a low cost and can be discarded after each test, avoiding cross - contamination. 4. **High sensitivity**: The system adopts a sub - wavelength grating metamaterial microring resonator and detects biomarkers through surface refractive index changes, showing extremely high sensitivity. For example, the system can monitor 10 μg/mL of streptavidin in real - time based on the biotin - streptavidin binding reaction. 5. **Versatility**: By immobilizing different specific receptors on the sensor surface, the system can be applied to various application scenarios such as heavy metal detection, gas sensing, virus detection and cancer marker diagnosis. In conclusion, the goal of this research is to develop a miniaturized, automated, low - cost and highly - sensitive portable biosensing system to meet the needs of remote areas and point - of - care testing.