Two-Photon Dual-Comb LiDAR

Hollie Wright,Jinghua Sun,David McKendrick,Nick Weston,Derryck T. Reid
DOI: https://doi.org/10.48550/arXiv.2108.10146
2021-08-19
Abstract:The interferometric signals produced in conventional dual-comb laser ranging require femtosecond lasers with long-term f_CEO stability, and are limited to an upper sampling rate by radio-frequency aliasing considerations. By using cross-polarized dual combs and two-photon detection we demonstrate carrier-phase-insensitive cross-correlations at sampling rates of up to 12x the conventional dual-comb aliasing limit, recording these in a digitizer-based acquisition system to implement ranging with sub-100-nm precision. We then extend this concept to show how the high data burden of conventional dual-comb acquisition can be eliminated by using a simple microcontroller as a ns-precision stopwatch to record the time intervals separating the two-photon cross-correlation pulses, providing real-time and continuous LiDAR-like distance metrology capable of sub-100 nm precision and dynamic acquisition for unlimited periods.
Instrumentation and Detectors,Optics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the upper limit of the sampling rate limitation due to the radio - frequency aliasing effect in traditional dual - comb laser ranging, and the complexity brought by the need for a long - term stable carrier - envelope - offset frequency (\(f_{CEO}\)). Specifically, the traditional method requires the use of a femtosecond laser with long - time stability, and the sampling rate is limited by radio - frequency aliasing considerations. These problems limit the performance and application range of the system. To solve these problems, the author proposes a two - photon - detection - based dual - comb LiDAR system. This method utilizes cross - polarized dual - combs and two - photon detection to achieve cross - correlation unaffected by the carrier phase, and the sampling rate can reach 12 times the traditional dual - comb aliasing limit. In addition, by using a simple microcontroller as a nanosecond - precision timer to record the time interval between two - photon cross - correlation pulses, the high data burden in traditional dual - comb acquisition is eliminated, providing real - time continuous LiDAR - type distance measurement with an accuracy of sub - 100 nanometers and enabling dynamic acquisition indefinitely. In short, the main objective of the paper is to overcome the sampling rate limitation and carrier - envelope - offset - frequency stability requirements in traditional dual - comb laser ranging by introducing the two - photon dual - comb cross - correlation technique, thereby achieving more accurate and efficient distance measurement.