Abstract:Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a rotating waveplate-based polarimeter capable of complete Stokes vector analysis of collimated light. Calibration of the device allows accurate measurements over a range of wavelengths, with a bandwidth of >30 nm in this implementation. A photo-interrupter trigger system supplies the phase information necessary for full determination of the Stokes vector. An Arduino microcontroller performs rapid analysis and displays the results on a liquid crystal display. The polarimeter is compact and can be placed anywhere on an optical table on a single standard post. The components to construct the device are only a fraction of the cost of commercially available devices while the accuracy and precision of the measurements are of the same order of magnitude.
Instrumentation and Detectors,Optics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to accurately measure the polarization state of light, especially how to achieve the analysis of the complete Stokes vector of light. Specifically, the authors have developed a portable polarimeter based on a rotating quarter - wave plate (λ/4 plate, QWP). This device is able to: 1. **Accurately measure the polarization state**: By calibrating the device, accurate measurements can be made within a certain wavelength range, with a bandwidth exceeding 30 nanometers. 2. **Provide complete Stokes vector analysis**: Use a photo - electric interrupter - triggered system to provide phase information to determine the complete Stokes vector. 3. **Achieve rapid data analysis and display**: Utilize an Arduino microcontroller for rapid analysis and display the results on a liquid - crystal display. 4. **Be compact in design and low - cost**: The entire device can be mounted on a standard optical mount, with a cost far lower than that of commercial devices but with comparable measurement accuracy. ### Main technical details - **Optical components**: The device mainly consists of a rotating quarter - wave plate (QWP), a fixed linear polarizer (analyzer), and a photodiode. - **Signal processing**: The light intensity signal detected by the photodiode is analyzed by fast Fourier transform (FFT) to extract the Stokes parameters. - **Calibration method**: Measure the angular phase of the QWP relative to the polarizer through a photo - electric interrupter and a timing disk to ensure that the position of the fast axis of the QWP is known at the start of each rotation cycle. - **Software adjustment**: Use software offset to correct the physical phase angle to ensure the accuracy of the measurement. ### Application background The polarization state of light is crucial in many optical experiments, such as: - **Coupling to polarization - maintaining fibers**: It is necessary to match the polarization of the input beam with the polarization axis of the fiber. - **Selective excitation of quantum emitters**: For example, in optical transitions in atoms or quantum dots, the polarization state of the incident laser needs to match the dipole moment of the required transition. - **Calibration of liquid - crystal variable retarders (LCVR)**: It is necessary to accurately know the polarization state of the laser as a reference. Therefore, the method and device proposed in this paper have wide application value and importance in optical experiments.