Instant Detection of Cerebral Blood Flow Changes in Infants with Congenital Heart Disease during Transcatheter Interventions

Martin Leth-Olsen,Gaute Døhlen,Hans Torp,Siri Ann Nyrnes
DOI: https://doi.org/10.3390/jcm13113115
IF: 3.9
2024-05-27
Journal of Clinical Medicine
Abstract:Background: Transcatheter interventions are increasingly used in children with congenital heart disease. However, these interventions can affect cardiac output and cerebral circulation. In this pilot study, we aimed to investigate the use of NeoDoppler, a continuous transfontanellar cerebral Doppler monitoring system, to evaluate the impact of transcatheter interventions on cerebral circulation. Methods: Nineteen participants under one year of age (mean age 3.5 months) undergoing transcatheter cardiac interventions were prospectively included. Transfontanellar cerebral Doppler monitoring with the NeoDoppler system was initiated after intubation and continued until the end of the procedure. Results: Instant detection of changes in cerebral blood flow were observed across a spectrum of transcatheter interventions. Balloon aortic valvuloplasty demonstrated temporary cessation of cerebral blood flow during balloon inflation. Increase in cerebral diastolic blood flow velocity and decreased pulsatility were observed during patent ductus arteriosus occlusion. Changes in cerebral blood flow patterns were detected in two patients who encountered complications during their transcatheter interventions. There was no significant change in Doppler parameters before and after the interventions for the entire patient group. High quality recordings were achieved in 87.3% of the monitoring period. Conclusions: Continuous transfontanellar cerebral Doppler is feasible in monitoring cerebral hemodynamic trends and shows instantaneous changes associated with interventions and complications. It could become a useful monitoring tool during transcatheter interventions in infants.
medicine, general & internal
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is the real - time detection of cerebral blood flow changes in infants undergoing transcatheter interventional treatment for congenital heart disease (CHD). Specifically, the researchers hope to evaluate the impact of these interventional surgeries on the cerebral circulation by using the NeoDoppler system, a continuous transcranial Doppler monitoring system through the anterior fontanelle. The main objectives of the study include: 1. **Evaluating technical feasibility**: Verifying the feasibility and reliability of using continuous transcranial Doppler monitoring through the anterior fontanelle in infants. 2. **Instantly detecting changes**: Observing and recording the changes in cerebral blood flow during different types of transcatheter interventional surgeries, especially whether these changes can be detected instantly. 3. **Identifying complications**: Exploring whether this monitoring system can identify complications during the surgical process at an early stage, such as cardiac tamponade, etc. 4. **Safety assessment**: Evaluating the safety of using the NeoDoppler system, especially its impact on infants during long - term monitoring. Through these objectives, the study aims to provide clinicians with an effective tool to better monitor and protect the brain function of infants during complex transcatheter interventional surgeries.