Investigation of mechanical properties of soft hydrogel microcapsules in relation to protein delivery using a MEMS force sensor.

Keekyoung Kim,Ji Cheng,Qun-qi Liu,X. Wu,Yu Sun
DOI: https://doi.org/10.1002/jbm.a.32338
Abstract:This article reports the investigation of mechanical properties of alginate-chitosan microcapsules and the relation to protein delivery. For microscale compression testing, a system based on a microelectromechanical systems (MEMS) capacitive force sensor was developed. The bulk microfabricated capacitive force sensors are capable of resolving forces up to 110 microN with a resolution of 33.2 nN along two independent axes. The monolithic force sensors were directly applied to characterizing mechanical properties of soft hydrogel microparticles without assembling additional end-effectors. Protein-loaded alginate-chitosan microcapsules of approximately 20 mum in diameter were prepared by an emulsion-internal gelation-polyelectrolyte coating method. Young's modulus values of individual microcapsules with 1, 2, and 3% chitosan coating were determined through microscale compression testing in both distilled deionized (DDI) water and pH 7.4 phosphate-buffered saline (PBS). Protein release rates were also determined in DDI water and PBS. Finally, protein release rates were correlated with mechanical properties of the microcapsules.
What problem does this paper attempt to address?