Magnetically induced magnetosome chain (MAGiC):A biogenic magnetic-particle-imaging tracer with high performance and navigability

Lei Li,Chan Zhao,Zhiyuan Zhao,Dou Han,Yidong Liao,Yanjun Liu,Sijia Liu,Xiaohua Jia,Jiesheng Tian,Qing Liu,Xin Feng,Jie Tian
DOI: https://doi.org/10.1101/2024.12.04.626925
2024-12-09
Abstract:Magnetic particle imaging (MPI) enables real-time, sensitive and quantitative visualization of magnetic tracers' spatial distribution, augmenting the capability of in vivo imaging technologies. Previous tracer studies in MPI have primarily focused on superparamagnetic nanoparticles; however, their non-ideal sigmoidal magnetization response limits the spatial resolution. Here we demonstrate the utilization of magnetically induced magnetosome chain (MAGiC) as a novel superferromagnetic MPI tracer, exhibiting a 25-fold improvement in resolution and a 91-fold enhancement in signal intensity compared to the commercial tracer VivoTrax+. The spatial resolution of MPI was pushed to an unprecedented 80 μm under a 4 T/m gradient field. Additionally, MAGiC can be precisely controlled using magnetic fields, enabling it to function as a MPI trackable microrobot. We provided a theoretical model elucidating MAGiC's unique properties, and validated its imaging and actuation performance through phantom studies and in vivo experiments. As a high-performance MPI tracer and magnetic microrobot with exceptional capabilities, MAGiC holds tremendous potential for diverse applications including cell tracking, targeted drug delivery as well as therapeutic interventions.
Bioengineering
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the limitations of existing magnetic tracers in Magnetic Particle Imaging (MPI) technology in terms of spatial resolution and signal intensity. Specifically: 1. **Limitations of Existing MPI Tracers**: - Currently commonly - used superparamagnetic nanoparticles limit the spatial resolution of MPI due to their non - ideal S - shaped magnetization response. - Commercial MPI tracers such as VivoTrax+™ perform poorly in terms of resolution and signal intensity. 2. **Proposed New Solution**: - The paper introduces a new type of biogenic magnetic tracer - Magnetically Induced Magnetosome Chain (MAGiC). This tracer exhibits superferromagnetism and has significantly improved resolution and signal intensity. - Research shows that the spatial resolution of MAGiC reaches an unprecedented 80 μm in a 4 T/m gradient field, and compared with the commercial VivoTrax+™ tracer, the resolution is improved by 25 times and the signal intensity is enhanced by 91 times. 3. **Multifunctional Application Potential**: - In addition to being a high - performance MPI tracer, MAGiC can also be precisely controlled by an external magnetic field, enabling it to function as a trackable microrobot. - This property makes MAGiC have broad application prospects in cell tracking, targeted drug delivery, and therapeutic intervention. ### Key Problem Summary - **Improving the Spatial Resolution and Signal Intensity of MPI**: By developing a new superferromagnetic tracer MAGiC, the deficiencies of existing MPI tracers in resolution and signal intensity are solved. - **Realizing the Function of Magnetic Microrobot**: MAGiC can not only be used as a high - resolution MPI tracer but also be navigated and controlled by a magnetic field, expanding its application range in the biomedical field. ### Formula Representation The physical models and experimental results mentioned in the paper involve some key parameters, for example: - The relationship between the Full Width at Half Maximum (FWHM) of the magnetization curve and MPI performance: \[ \text{FWHM}=\frac{\Delta H}{\sqrt{2\ln(2)}} \] where \(\Delta H\) is the width of the magnetization curve. - The dynamic process of magnetization response: \[ M(H) = M_s\tanh\left(\frac{\mu_0H}{k_BT}\right) \] where \(M_s\) is the saturation magnetization intensity, \(\mu_0\) is the magnetic permeability in vacuum, \(H\) is the applied magnetic field, \(k_B\) is the Boltzmann constant, and \(T\) is the temperature. These formulas are used to explain the magnetization response of MAGiC and its influence on MPI performance.