Nonlinear Singular Value Decomposition Beamforming for Ultrasound Imaging of Gas Vesicles

Ge Zhang,Mathis Vert,Mohamed Nouhoum,Esteban Rivera,Nabil Haidour,Anatole Jimenez,Thomas Deffieux,Simon Barral,Pascal Hersen,Claire Rabut,Mikhail Shapiro,Mickael Tanter
DOI: https://doi.org/10.1101/2024.10.14.618186
2024-10-16
Abstract:Ultrasound imaging holds significant promise for the observation of molecular and cellular phenomena through the utilization of acoustic contrast agents and acoustic reporter genes. Optimizing imaging methodologies for enhanced detection represents an imperative advancement in this field. Most advanced techniques relying on amplitude modulation scheme such as cross amplitude modulation (xAM) and ultrafast amplitude modulation (uAM) combined with Hadamard encoded multiplane wave transmissions have shown efficacy in capturing acoustic signals of gas vesicles (GVs). Nonetheless, uAM sequence requires odd- or even-element transmissions leading to imprecise amplitude modulation emitting scheme, and the complex multiplane wave transmission scheme inherently yields overlong pulse durations. xAM sequence is limited in terms of field of view and imaging depth. To overcome these limitations, we introduce an innovative ultrafast imaging sequence called nonlinear singular value decomposition (SVD) beamforming. Our method demonstrated a contrast imaging sensitivity comparable to the current gold-standard xAM and uAM, while requiring 4.8 times less pulse transmissions. With similar number of transmit pulses, nonlinear SVD beamforming outperforms xAM and uAM in terms of an improvement in signal-to-background ratio of + 4.78 dB and + 8.29 dB respectively. Additionally, our method provides a higher flexibility in terms of the selection of acoustic pressure amplitude compared to the other methods. Furthermore, it shows a significant potential for application in the realm of ultrasound localization microscopy (ULM), where it stands poised to facilitate the more precise extraction of nonlinear signatures originating from contrast agents.
Biophysics
What problem does this paper attempt to address?
The problems that this paper attempts to solve are the limitations of existing ultrasonic imaging techniques in detecting gas vesicles (GVs), including complex pulse transmission schemes, overly long pulse durations, and limited imaging depth and field of view. Specifically: 1. **Limitations of existing amplitude modulation methods (such as cross - amplitude modulation xAM and ultrafast amplitude modulation uAM)**: - **uAM sequence**: It requires the transmission of odd or even elements, resulting in an imprecise amplitude - modulation emission scheme, and the complex multi - plane - wave transmission scheme will make the pulse duration too long. - **xAM sequence**: There are limitations in terms of field of view and imaging depth. 2. **The need to improve ultrasonic imaging techniques**: - Existing techniques have limited ability to capture rapid nonlinear events and eliminate tissue motion artifacts, especially in deep tissues. - A more efficient and flexible method is required to optimize imaging performance while reducing the number of required pulse transmissions and acoustic transmission energy. To solve these problems, the author introduced a new ultrafast nonlinear singular value decomposition (SVD) beamforming technique. This technique aims to significantly simplify the transmission pulse sequence while achieving better contrast - imaging sensitivity and significantly reducing the acoustic transmission energy, thus surpassing the current state - of - the - art uAM and xAM imaging schemes. ### Specific Objectives - **Improve imaging sensitivity**: Through the nonlinear SVD beamforming technique, achieve contrast - imaging sensitivity comparable to the existing gold - standard xAM and uAM. - **Reduce the number of pulse transmissions**: Compared with existing methods, the new method requires only 4.8 times fewer pulse transmissions. - **Improve signal - to - noise ratio**: With the same number of transmitted pulses, the nonlinear SVD beamforming technique improves the signal - to - background ratio (SBR) by +4.78 ± 0.35 dB and +8.29 ± 3.52 dB respectively. - **Enhance flexibility**: Provide greater flexibility, allowing the selection of different sound - pressure amplitudes. - **Expand application areas**: Have potential applications in the field of ultrasound localization microscopy (ULM) and be able to extract nonlinear signals from contrast agents more accurately. ### Summary The main purpose of this research is to develop an ultrafast nonlinear SVD beamforming technique to significantly simplify the transmission pulse sequence while achieving better contrast - imaging sensitivity and significantly reducing the acoustic transmission energy, thus surpassing the existing uAM and xAM imaging schemes.