Reproducibility of different methods of measuring left ventricular ejection fraction in echocardiography

Ikuko Kawagishi,Masaya Hashimoto,Yuki Endo,Soma Ono,Miyabi Takamuku,Kazunori Ohnishi
DOI: https://doi.org/10.1101/2024.10.10.24315216
2024-10-10
Abstract:Background: Left ventricular ejection fraction (LVEF) measurements by echocardiography are subject to problems such as low interobserver reproducibility, which depends on the skill of the observer, and variations in measurement technique. Objective: We investigated the reproducibility of echocardiography by comparing the measurement results of a certified sonographer with those of control students. Methods: A total of 30 subjects, 22 adult students and 8 staff members of Shubun University, were included in the study. Measurements were performed according to the standard protocols of the Japanese Society of Echocardiography. Results: LVEF values were significantly lower with the modified Simpson method than with the Teichholz method (M-mode and B-mode) for both the sonographer and students; there was no difference between the M-mode and B-mode approaches for the sonographer, but B-mode was significantly lower for students. Comparing the sonographer and students, there was no significant difference with the M-mode approach, but students had significantly lower values with the B-mode and modified Simpson methods. Although the modified Simpson method is currently recommended for LVEF measurement, the lower values obtained by students using this method are primarily attributed to their inexperience with the measurement technique. Conclusions: In the future, the evaluation of cardiac function by echocardiography will require reproducibility that does not rely on the skill of the observer, and the adoption of echocardiography methods incorporating artificial intelligence is anticipated.
Cardiovascular Medicine
What problem does this paper attempt to address?
The paper attempts to address the issue of reproducibility in echocardiographic measurement of left ventricular ejection fraction (LVEF). Specifically, the study focuses on the consistency and accuracy of LVEF measurements between different operators (certified sonographers and students) using different methods (Teichholz method and modified Simpson method). The main objectives of the paper are: - To compare the measurement results of certified sonographers and students, evaluating the reproducibility of different methods. - To investigate the impact of different measurement techniques on LVEF values. - To analyze the difficulties encountered by novice operators (such as students) when using complex measurement methods. Through these analyses, the paper aims to improve the reliability and standardization of echocardiographic LVEF measurements and explore the potential of adopting artificial intelligence technology to enhance measurement methods in the future.