Non-invasive Real-time Detection of Potassium level Changes in Skeletal Muscles during Exercise by Magnetic Resonance Spectroscopy

Etienne Roesli,Hedvika Primasova,Marc Thiede,Laila-Yasmin Mani,Lena Gast,Armin Nagel,Bruno Vogt,Peter Vermathen
DOI: https://doi.org/10.1101/2024.09.30.24314637
2024-10-01
Abstract:Introduction: Potassium is essential in cellular functions, with specific importance in muscle activity and cardiovascular health. It is the main intracellular cation in the human body with 70% located in muscle. Traditional methods to measure potassium levels are invasive and lack specificity for intracellular concentrations. Recently, non-invasive in vivo investigation of K+ ion homeostasis has become feasible by using 39K Magnetic Resonance Imaging (MRI) and MR spectroscopy (MRS) at ultrahigh magnetic fields. However, studies demonstrating the sensitivity of 39K MRI or MRS to detect potassium alterations in disease or upon intervention are sparse. This study utilizes 39K MRS to non-invasively track real-time intramuscular potassium changes during exercise, providing an assessment of potassium dynamics and explores the potential for technical artifacts in the measurements. Methods: Five healthy subjects (three males, two females) were recruited to perform standardized dynamic knee extensions inside a 7T MR scanner. Potassium levels were measured using a 39K MRS protocol that included periods of rest, moderate, and heavy exercise followed by recovery. Additionally, possible measurement artifacts due to muscle movement or changes in coil position relative to the thigh were evaluated using 39K MRS and 1H MRI monitoring in separate sessions. Results: The study revealed a consistent decrease in potassium levels during both moderate and heavy exercise, with an average decrease of 5-6%. These changes were rapidly detectable and were reversed upon cessation of exercise, indicating effective in vivo monitoring capability. Possible experimental artifacts were investigated, and the results suggested not to be responsible for the detected potassium changes during exercise. The results of the non-localized 39K MRS measurements during exercise correlated well with expected physiological changes based on previous literature. Discussion: The application of 39K MRS provides a valuable non-invasive tool for studying potassium dynamics in human skeletal muscle. This technique could enhance our understanding of muscle physiology and metabolic disorders. The ability to measure these changes in real time and non-invasively highlights the potential for clinical applications, including monitoring of diseases affecting muscle and cellular metabolism.
Radiology and Imaging
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: **How to non - invasively and real - time detect the changes in potassium ion concentration in skeletal muscle during exercise**. ### Background and Problem Description Potassium ions (K⁺) play a crucial role in cell functions, especially in muscle activity and cardiovascular health. Approximately 70% of potassium in the human body is located in muscle tissues. Therefore, understanding the changes in potassium concentration within muscles during exercise is of great significance for understanding muscle physiology and metabolic disorders. Traditional methods for measuring potassium concentration are usually invasive and lack specificity for intracellular concentration. In recent years, it has become possible to conduct non - invasive in - vivo studies using ³⁹K magnetic resonance spectroscopy (MRS) and magnetic resonance imaging (MRI) in an ultra - high magnetic field, but there are still few related sensitivity and feasibility studies. ### Research Objectives The main objectives of this study are: 1. **To use ³⁹K MRS technology to non - invasively and real - time monitor the changes in potassium concentration in skeletal muscle during exercise**. 2. **To evaluate the feasibility and sensitivity of this technology** to determine whether exercise - induced changes in potassium concentration can be reliably detected. 3. **To explore possible technical artifacts**, such as the influence of muscle movement or coil position changes on the measurement results, and ensure the accuracy of the measurement results. ### Method Overview - **Experimental Subjects**: Five healthy volunteers (three men and two women) participated in the main experiment, and another three volunteers were used for artifact analysis. - **Experimental Equipment**: A 7T MRI scanner and a customized ³⁹K/¹H dual - tuned surface coil were used. - **Experimental Design**: Volunteers performed standardized dynamic knee - extension exercises inside the MRI scanner, which were divided into four stages: rest, moderate - intensity exercise, high - intensity exercise, and recovery, with different durations for each stage. Potassium concentration changes were recorded by ³⁺K MRS, and potential artifacts were monitored by ¹H MRI. ### Results and Discussion The research results showed that during moderate - intensity and high - intensity exercise, the potassium concentration decreased by an average of 5 - 6%, and these changes recovered rapidly after exercise stopped. In addition, through additional experimental verification, the influence of artifacts caused by muscle movement or coil position changes on the measurement results was excluded. In conclusion, this study has proven that ³⁹K MRS technology can non - invasively and real - time monitor the changes in potassium concentration in skeletal muscle during exercise, providing a valuable tool for future research and clinical applications.