Breathome discriminate Ischemic Heart Disease

Basheer Abdullah Marzoog,Peter Chomakhidze,Daria Gognieva,Nina Vladimirovna Gagarina,Artemiy Silantyev,Alexander Suvorov,Ekaterina Fominykha,Philipp Kopylov
DOI: https://doi.org/10.1101/2024.07.15.24310414
2024-07-16
Abstract:Background: Ischemic heart disease (IHD) impacts the quality of life and has the highest mortality rate in between other cardiovascular disease in the globe. Objectives: IHD early diagnosis, management, and prevention remain underestimated due to the poor diagnostic and therapeutic strategies including the early prevention methods. Aims: To assess the changes in the exhaled breath analysis, volatile organic compounds (VOCs), in patients with ischemic heart disease confirmed by stress computed tomography myocardial perfusion (CTP) imaging. Materials and methods: A single center observational study included 80 participants from Moscow. The participants aged ≥ 40 years and given a written consent to participate in the study. Both groups, G1=31 with vs G2=49 without post stress induced myocardial perfusion defect, passed cardiologist consultation, anthropometric measurements, blood pressure and pulse rate, echocardiography, real time breathing at rest into PTR-TOF-MS-1000, cardio-ankle vascular index, performing bicycle ergometry, and immediately after performing bicycle ergometry repeating the breathing analysis into the PTR-TOF-MS-1000, and after three minutes from the second breath, repeat the breath into the PTR-TOF-MS-1000, then performing CTP. LASSO regression with nested cross-validation was used to find association between VOCs and existence of perfusion defect. Statistical processing was carried out using the R programming language v4.2 and Python v.3.10 [^R], STATISTICA, and IBM SPSS. Results: The specificity 77.6 % [95 % confidence interval (CI); 0.666 ; 0.889], sensitivity 83.9 % [95 % CI ; 0.692 ; 0.964], and accuracy of the diagnostic method using exhaled breath analysis, area under the curve (AUC) 83.8 % [95 % CI ; 0.73655857 ; 0.91493173]. Whereas, the AUC of the bicycle ergometry 50.7 % [95 % CI ; 0.388 ; 0.625], specificity 53.1 % [95 % CI ; 0.392 ; 0.673], and sensitivity 48.4 % [95 % CI ; 0.306 ; 0.657]. Conclusion: VOCs analysis appear to discriminate individuals with and without IHD with clinically acceptable diagnostic accuracy. Other: The exhaled breath analysis reflects the myocardiocytes metabolomic signature and related intercellular homeostasis changes and regulation perturbances. Exhaled breath analysis poses a promise result to improve the diagnostic accuracy of the physical stress tests.
Cardiovascular Medicine
What problem does this paper attempt to address?