Single Channel Electrocardiography Optimizes the Diagnostic Accuracy of Bicycle Ergometry!

Basheer Abdullah Marzoog,Magomed Abdullaev,Alexander Suvorov,Peter Chomakhidze,Daria Gognieva,Nina Vladimirovna Gagarina,Natalia Mozzhukhina,Sergey Vladimirovich Kostin,Afina Aftandilovna Bestavashvili,Ekaterina Fominykha,Philipp Kopylov
DOI: https://doi.org/10.1101/2024.04.20.24306122
2024-06-08
Abstract:Background: Ischemic heart disease (IHD) has the highest mortality rate in the globe. This returns to the poor diagnostic and therapeutic strategies including the early prevention methods. Aims: To assess the changes in the single channel electrocardiography (SCECG) at rest and on exercise test in patients with vs without IHD confirmed by stress computed tomography myocardial perfusion (CTP) imaging with vasodilatation stress-test. Objectives: IHD frequently have preventable risk factors and causes that lead to the disease appearance. However, the lack of the proper diagnostic and prevention tools remains a global challenge in or era despite the current scientific advances. Material and methods: A single center observational study included 38 participants from Moscow. The participants aged ≥ 40 years and given a written consent to participate in the study. Both groups, G1=19 with vs G2=19 without post stress induced myocardial perfusion defect, passed consultation by cardiologist, anthropometric measurements, blood pressure and pulse rate, echocardiography, cardio-ankle vascular index, performing bicycle ergometry, recording 3-minutes SCECG (using CARDO-QVARK ) before and just after bicycle ergometry, and then performing CTP. The LASSO regression with nested cross-validation was used to find association between CARDO-QVARK parameters and the existence of the perfusion defect. Statistical processing carried out using the R programming language v4.2 and Python v.3.10 [^R]. Results: The CARDO-QVARK parameters analysis have a specificity 63.2 % [95 % confidence interval (CI); 0.391 ; 0.833], sensitivity 73.7 % [95 % CI ; 0.533 ; 0.929], area under the curve (AUC) 68.4 % [95 % CI ; 0.527 ; 0.817] in compare to bicycle ergometry (AUC; 55.3 %), based on our study results. Conclusion: The SCECG have significantly higher diagnostic accuracy in compare to bicycle ergometry. CARDO-QVARK has the potential to improve the diagnostic accuracy of the bicycle ergometry. Other: Further investigations required to uncover the hidden capabilities of CARDO-QVARK in the diagnosis of ischemic heart disease.
What problem does this paper attempt to address?