Transcatheter closure of ventricular septal defects by exclusive transvenous antegrade cannulation from the right ventricle

Pramod Sagar,Puthiyedath Thejaswi,Ishita Garg,Kothandam Sivakumar
DOI: https://doi.org/10.1101/2024.05.28.24308078
2024-05-29
Abstract:Background: Transcatheter closure(TCC) of perimembranous ventricular septal defects(PM-VSD) and intraconal defects routinely involves either arteriovenous loop formation or direct retrograde device deployment from its left ventricular(LV) end. An arterial access is always taken for a left ventriculogram. Direct antegrade cannulation of the defect from the right ventricle for TCC avoids complications associated with femoral arterial access and arteriovenous loop formation. Methods: Feasibility of elective antegrade cannulation for TCC of PM-VSD, intraconal VSD and postoperative residual VSD was retrospectively studied over five years from 2019-2023. Echocardiographic VSD measurements guided the device selection rather than left ventriculographic measurements. Predictors for successful antegrade cannulation and transvenous device deployment were analyzed. Results: Antegrade cannulation was electively attempted in 116/163(71%) TCC VSD closure procedures. The proportion of cases where this antegrade cannulation was electively employed progressively increased from 26% of interventions performed in 2019 to 93% in 2023. The median age of the study cohort that included 24 infants was 55 months (range 1-636 months) and the indexed VSD size was 9.2 mm/m2 (range 1.7-43.3 mm/m2). Two-thirds of patients had varying degrees of pulmonary arterial hypertension. Antegrade cannulation was successful in 97(83.6%) patients. In the remaining 19 patients, retrograde cannulation from LV aided TCC. There were no deaths or need for pacemaker implantation. Overall procedural success of TCC in this cohort was 99.1%.Device embolization with tricuspid chordal tear led to procedural failure in one patient. Four other device embolizations were managed successfully by transcatheter retrieval and closure with an upsized device. Young age, small body size, large VSD size were significantly associated with successful antegrade cannulation. Conclusions: Antegrade cannulation and TCC was feasible in majority of the procedures, especially in small patients and large defects. This strategy simplified the procedure without arterial access and might replace the routine retrograde device delivery and AV loop formation.
What problem does this paper attempt to address?