Design and development of ultraviolet germicidal irradiation device for controlling airborne bacteria in the workplace

Witaya Yoosook,Pornpimol Kongtip,Suttinun Chantanakul
Abstract:Objective: To design and develop an ultraviolet germicidal irradiation (UVGI) device for controlling airborne bacteria in the workplace of hospitals. Material and method: The constructed UVGI device was a chamber, consisting of a return air grille, an air supply grille, two 30-watt ultraviolet lamps and a cross flow fan inside the chamber. The efficiency of the UVGI device was tested at three different flow rates of 15.7, 31.6 and 46.1 m3/min, respectively by collecting bacteria samples before and after operating the device for 30, 60, 90 and 120 minutes. Results: The efficiency of the UVGI device at flow rates of 15.7, 31.6 and 46.1 m3/min was 60.6, 92.8 and 80.8%, respectively and the bacteria concentration was reduced to less than 100 cfu/m3, except at the flow rate of 15.7 m3/min. The application of the UVGI device in the specimen-received room showed that the concentration of bacteria was reduced to less than 100 cfu/m3 after 180 minutes. Conclusion: The constructed UVGI device was effective to reduce airborne bacteria in workplace of hospital.
What problem does this paper attempt to address?