Phase diversity-based wavefront sensing for fluorescence microscopy

Courtney Johnson,Min Guo,Magdalena C. Schneider,Yijun Su,Satya Khuon,Nikolaj Reiser,Yicong Wu,Patrick La Riviere,Hari Shroff
DOI: https://doi.org/10.1101/2023.12.19.572369
2024-01-02
Abstract:Fluorescence microscopy is an invaluable tool in biology, yet its performance is compromised when the wavefront of light is distorted due to optical imperfections or the refractile nature of the sample. Such optical aberrations can dramatically lower the information content of images by degrading image contrast, resolution, and signal. Adaptive optics (AO) methods can sense and subsequently cancel the aberrated wavefront, but are too complex, inefficient, slow, or expensive for routine adoption by most labs. Here we introduce a rapid, sensitive, and robust wavefront sensing scheme based on phase diversity, a method successfully deployed in astronomy but underused in microscopy. Our method enables accurate wavefront sensing to less than λ/35 root mean square (RMS) error with few measurements, and AO with no additional hardware besides a corrective element. After validating the method with simulations, we demonstrate calibration of a deformable mirror > 100-fold faster than comparable methods (corresponding to wavefront sensing on the ~100 ms scale), and sensing and subsequent correction of severe aberrations (RMS wavefront distortion exceeding λ/2), restoring diffraction-limited imaging on extended biological samples.
Bioengineering
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the degradation of image quality in fluorescence microscopy due to optical aberrations. Specifically, the refractive properties of biological tissues or the misalignment of the optical system can cause distortion of the light wavefront, thereby reducing the contrast, resolution, and signal intensity of the image and affecting the imaging quality. Adaptive optics (AO) technology can restore image quality by sensing and correcting these distorted wavefronts, but existing AO methods have limitations in terms of complexity, efficiency, speed, or cost, and are difficult to be routinely adopted by most laboratories. To this end, the author introduced a fast, sensitive, and robust wavefront - sensing scheme based on phase diversity (PD). This method can achieve wavefront sensing with sub - wavelength accuracy under a small number of measurements and does not require additional hardware (except for a correction element). Through simulation verification and experimental demonstration, this method can calibrate the deformable mirror more than 100 times faster than existing methods, and can sense and correct severe aberrations to restore the diffraction - limited imaging of extended biological samples.