Development of a Battery-Free, Chipless, and Highly Sensitive Radio Frequency Glucose Biosensor

Md. Rajibur Rahaman Khan
DOI: https://doi.org/10.3390/mi15020272
IF: 3.4
2024-02-15
Micromachines
Abstract:In our study, we designed and developed a glucose biosensor that operates without a battery or chip. This biosensor utilizes the principles of radio frequency (RF) to operate. For the construction of a glucose-sensitive interdigitated capacitor (IDC), a famous glucose-sensitive substance called phenylboronic acid (PBA) is combined with a polyvinyl chloride (PVC) and n,n-dimethylacetamide (DMAC) solution. According to the theory of radio frequency sensing, the resonance frequency shifts whenever there is a change in the capacitance of the glucose-sensitive IDC. This change is caused by the fluctuations in glucose concentrations. As far as we are aware, this is the first glucose sensor that employs the RF principle to detect changes in glucose solution concentrations using PBA as the principal glucose-sensitive material. The sensor can detect glucose levels with remarkable sensitivity, around 40.89 kHz/decade, and a broad dynamic range covering 10 μM to 1 M. Additionally, the designed biosensor has excellent linearity performance, with a value of around 0.988. The proposed glucose biosensor has several benefits: lightweight, inexpensive, easy to build, and an acceptable selectivity response. Our study concludes by comparing the proposed RF sensor's effectiveness to that of existing glucose sensors, which it outperforms.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a battery - free, chip - free and highly sensitive radio - frequency glucose biosensor. Specifically, the researchers designed a glucose biosensor based on the radio - frequency (RF) principle, which utilizes a combination of an interdigitated capacitor (IDC) and a planar inductor. This sensor uses phenylboronic acid (PBA) as the main glucose - sensitive material and combines polyvinyl chloride (PVC) and N,N - dimethylacetamide (DMAC) solution to prepare a glucose - sensitive dielectric material. When the glucose solution comes into contact with this dielectric material, the capacitance of the IDC will change, resulting in a change in the resonant frequency of the sensor. This change can be used to detect the change in glucose concentration. The main problems mentioned in the paper include: 1. **Improving the sensitivity of glucose detection**: Existing glucose sensors are often not sensitive enough when detecting low - concentration glucose, while this research improves the sensitivity of the sensor to detect low - to - high - concentration glucose through the radio - frequency method. 2. **Broadening the dynamic detection range**: This sensor can perform linear detection in the glucose concentration range from 10 µM to 1 M, which is wider than that of many existing sensors. 3. **Reducing manufacturing cost and complexity**: The design of this sensor is simple, low - cost, easy to manufacture, and has good reproducibility and stability. 4. **Improving selectivity**: By using a specific glucose - sensitive material (PBA), this sensor shows high selectivity when detecting glucose and can effectively distinguish other interfering substances. In conclusion, this research aims to develop a highly efficient, low - cost glucose biosensor suitable for a variety of application scenarios.