Recovery of platinum group elements from waste material

A. M. Ngcephe
2019-06-01
Abstract:The aim of this study was to recover the platinum group elements (PGE) from recycled or waste material using hydrometallurgical techniques. The waste material that was investigated for the possible isolation of PGE is a spent automotive catalytic converter sample, ERM®-EBS504 which is a certified reference material for Pt, Pd and Rh. Surface analysis on the catalyst sample was performed using the scanning electron microscope coupled with energy dispersive X-ray spectroscopy (SEM-EDS) in order to identify the main components of the sample. However, the identification and quantification of the PGE using this technique was ineffective due to the concentrations of PGE in the catalyst sample which were below the detection limits of the SEM-EDS. Two types of dissolution processes, namely aqua-regia open-beaker dissolution and sodium peroxide (Na2O2) fusion were employed to try and achieve the total dissolution of the automotive catalytic converter sample for the complete and accurate characterisation of PGE using the inductively coupled plasma optical emission spectroscopy (ICP-OES). Aqua-regia dissolution offered partial digestion of the sample and percentage recoveries of 66.9(4) %, 63.9(8) % and 41(1) % were obtained for Pt, Pd and Rh respectively at 80 °C and after a reaction time of 180 minutes. On the other hand, sodium peroxide was able to oxidise all the metals in the catalyst sample to easily soluble oxidation states which allowed for the further dissolution of the sample in aqua-regia. However, challenges in PGE quantification with the ICP-OES were experienced due to unacceptable and unsatisfactory PGE recoveries which were attributed to spectral interferences caused by the excess Na ions introduced from the Na2O2 flux. The introduction of Sc (361.363 nm) as an internal standard compensated effectively for the spectral interference and excellent PGE recoveries were obtained, namely 100(1) % for Pt, 100(3) % for Pd and 103(2) % for Rh. These results were successfully validated in accordance with the criteria of the Internal Standards Organisation (ISO 17025). This method was found suitable and reliable for the quantification of PGE in the automotive catalyst sample at different separation stages. The complete digestion and characterisation of the automotive catalyst sample enabled separation studies of PGE in various aqueous solutions.
Chemistry,Environmental Science,Materials Science
What problem does this paper attempt to address?