DOTIFS: fore-optics and calibration unit design

Haeun Chung,A. N. Ramaprakash,Pravin Khodade,Chaitanya V. Rajarshi,Sabyasachi Chattopadhyay,Pravin A. Chordia,Amitesh Omar,Changbom Park
DOI: https://doi.org/10.48550/arXiv.1810.03627
2018-10-08
Instrumentation and Methods for Astrophysics
Abstract:We present fore-optics and calibration unit design of Devasthal Optical Telescope Integral Field Spectrograph (DOTIFS). DOTIFS fore-optics is designed to modify the focal ratio of the light and to match its plate scale to the physical size of Integral Field Units (IFUs). The fore-optics also delivers a telecentric beam to the IFUs on the telescope focal plane. There is a calibration unit part of which is combined with the fore-optics to have a light and compact system. We use Xenon-arc lamp as a continuum source and Krypton/Mercury-Neon lamps as wavelength calibration sources. Fore-optics and calibration unit shares two optical lenses to maintain compactness of the overall subsystem. Here we present optical and opto-mechanical design of the calibration unit and fore-optics as well as calibration scheme of DOTIFS.
What problem does this paper attempt to address?